background image

  

BURLEY G4121 

mk2 

FLUELESS GAS HEATER 

 

INSTALLATION, SERVICING 

& USER INSTRUCTIONS 

 

FOR USE IN THE COUNTRIES STATED ON THE DATA PLATE AND CARTON 

WITH NATURAL GAS G20 

OR LPG PROPANE GAS G31 

(REFER TO RATING LABEL) 

 

For the following countries: GB, IE 

 

EVEN IF YOU HAVE FITTED THESE FIRES BEFORE,  

PLEASE FOLLOW THESE INSTRUCTIONS STEP BY STEP. 

Legislation and regulations do change over time! 

 

LEAVE THESE INSTRUCTIONS WITH THE USER

 

 

 
 
 
 
 
 
 
 
 

 
 
Burley Appliances Ltd

,  

Lands End Way, Oakham, Rutland, LE15 6RB 
Telephone: +44 (0)1572 756956 Fax: +44 (0)1572 724390                           
e-mail: 

[email protected]

     web: 

www.burley.co.uk

  

G4121InstUser 

G20/31 

Issue JAN08 – v.1

 

TO OBTAIN YOUR FIRST YEAR GUARANTEE, THE INSTALLER AND CUSTOMER  

MUST FILL IN THE SEPARATE GUARANTEE AND RETURN IT TO  

BURLEY WITIHIN 7 DAYS OF FITTING. 

A FREE SECOND YEAR GUARANTEE IS OFFERED SUBJECT TO THE FIRE BEING SERVICED 

BY A CORGI ENGINEER DURING THE FIRST YEAR OF OWNERSHIP. 

PROOF OF SERVICING MUST BE RETAINED 

FAILURE TO HAVE THIS APPLIANCE FITTED BY A CORGI REGISTERED 

 FITTER INVALIDATES THE WARRANTY  

Содержание G4121 mk2

Страница 1: ...THE USER Burley Appliances Ltd Lands End Way Oakham Rutland LE15 6RB Telephone 44 0 1572 756956 Fax 44 0 1572 724390 e mail info burley co uk web www burley co uk G4121InstUser G20 31 Issue JAN08 v 1...

Страница 2: ...t High 3 5kW 3 5kW 250g h Low 1 7kW 1 7kW 120g h Inlet Connection 8mm Compression 8mm Compression Injector stereo 185 stereo 95 The inlet pressure must be within 1mBar of specification with all gas ap...

Страница 3: ...cubic feet by 35 3 Adjoining spaces not separated by a door may be combined 3 7 The heater must not be used on or against a combustible surface 3 8 No furniture soft furnishings decorations wall cove...

Страница 4: ...t for servicing 4 5 The surfaces of the appliance become very hot during use 4 6 Before cleaning or maintenance switch fire OFF and allow to cool 4 7 Any purpose provided ventilation should be checked...

Страница 5: ...etc All gas work should be undertaken by a competent person see General Requirements 8 Siting the Appliance 8 1 If the appliance is to be in or in front of an open fireplace the chimney or flue MUST b...

Страница 6: ...rner and the front log is pushed to the extreme left hand side as shown Take the 2 loose logs and position them as shown onto the cut outs on the base log taking care to locate them correctly to ensur...

Страница 7: ...f it does not light repeat the operation a few times Continue to hold knob for 15 20 sec s to establish the pilot and then release If pilot fails to establish turn off wait 1 minute then repeat lighti...

Страница 8: ...Protective clothing is not required but normal hygiene rules of no smoking eating or drinking in the work area should be followed Controls The system for monitoring the oxygen supply to the burner is...

Страница 9: ...IN THE UNIQUE POSITION OF KNOWING THAT EVERY APPLIANCE LEAVES THE FACTORY IN PERFECT WORKING ORDER Due to our policy of continual improvement and development the exact accuracy of descriptions and il...

Страница 10: ...956 Do not use any other type of paint GENERAL REQUIREMENTS 1 The heater is intended as a secondary heat source Check that a primary source of heat such as radiators is present in the room If insuffic...

Страница 11: ...e the fire purely as a heater in which case they will select a flame height then set the thermostat to a comfort level In both cases if the room gets too hot the thermostat will reduce the fire to pil...

Страница 12: ...obstructed TURN OFF PROCEDURE To extinguish the pilot turn the valve to the OFF position Note that if the gas supply fails at any time the pilot will extinguish Leave for one minute then carry out the...

Отзывы: