Technical Data
6.
TEchnical daTa
Operating conditions
6.1.
Warning!
danger of explosion!
The controller Type 1094 EV has a protection class of IP00 and is
not designed for use in the explosion-protected area. If it is used
in the area of tank installations, a short-circuit in the controller
could cause an explosion.
If it used in the area of a tank installation, the controller Type
•
1094 EV must be installed in a control cabinet with an appropri-
ate protection class.
Permitted ambient temperature: -25 – +55 °C
(icing over not permitted)
Permitted air humidity:
5 – 85 %
(condensation not permitted)
noTE!
damage to device caused by icy or wet conditions!
Icy and wet conditions may damage the device and cause
malfunctions.
Protect device from icy and wet conditions caused by dew, etc.
•
Protection class:
IP00, the electronics are designed for oper-
ation in the control cabinet only.
conformity with the following
6.2.
standards
CE mark compliant with
EMC generic emission standard
IEC-61000-6-1
IEC-61000-6-2
IEC-61000-6-3
IEC-61000-6-4
BImSchV
Bundes-Immissionsschutz-Verordnung
(Federal Emission Protection Ordinance)
21. BImSchV; Ordinance on the Restriction of
Hydrocarbon Emissions during the Refueling of
Vehicles
general Technical data
6.3.
Housing:
Open housing for installation on mounting rail in
accordance with DIN EN 50022 / DIN EN 50035 /
DIN EN 50045
Dimensions:
68 x 76 x 35 mm
Order number:
208373
English
Type 1094 EV
Содержание 1094 EV
Страница 4: ...4 11 Packaging Transport 26 12 Storage 27 13 Disposal 27 English Type 1094 EV ...
Страница 28: ...28 English Type 1094 EV ...
Страница 30: ...30 11 Verpackung Transport 52 12 Lagerung 53 13 Entsorgung 53 Typ 1094 EV deutsch ...
Страница 54: ...54 Entsorgung Typ 1094 EV deutsch ...
Страница 80: ...80 Type 1094 EV français ...
Страница 81: ......
Страница 82: ...www burkert com ...