17
Technical Data
Outputs / Motor contactor
6.5.4.
The output for the motor contactor is activated by the controller for as
long as the proportional valve is open.
This contactor/relay switches the vacuum pump motor.
Furthermore, a overtravel time can be set for the vacuum pump (motor
contactor) for which the signal remains active. If the overtravel is set
to 0s, the motor contactor is not activated. This function is useful for
defective motors.
Load current:
0 ... 150 mA
Output voltage:
24 V DC
Number of outputs: 2 (1 output each for side 1 and for side 2)
Output
µController
24 V
Connection
terminals
for motor
contactor
GND
Motor contact output of the controller Type 1094 EV
Fig. 7:
Operation as ac device at 230/115 V
6.5.5.
A power supply unit was installed for the operation of the vapor
recovery 1094 EV. This power supply unit has the following data:
Manufacturer:
TRACO POWER
Designation:
Industrial Power Supply
Model:
TBL 030-124
Power supply voltage:
100 ... 240 V 50/60 Hz -15 % / +10 %
Max. power consumption: 0,5 ... 0,9 A
Output voltage:
24 V DC ±10 %
Max. output current:
1.25 A
Max. output power:
30 W
Control Type 1094 EV with 24 V power supply unit
Fig. 8:
English
Type 1094 EV
Содержание 1094 EV
Страница 4: ...4 11 Packaging Transport 26 12 Storage 27 13 Disposal 27 English Type 1094 EV ...
Страница 28: ...28 English Type 1094 EV ...
Страница 30: ...30 11 Verpackung Transport 52 12 Lagerung 53 13 Entsorgung 53 Typ 1094 EV deutsch ...
Страница 54: ...54 Entsorgung Typ 1094 EV deutsch ...
Страница 80: ...80 Type 1094 EV français ...
Страница 81: ......
Страница 82: ...www burkert com ...