52
Warp Engine polling is fast, enabling real-time monitoring of up to 100 sites per second, with each site reporting as
many as 32 status and/or meter values. Larger networks just take a little longer, for example polling up to 500 sites
in 5 seconds. Warp Engine polling is efficient in its use of communications bandwidth. It uses very small packets,
sending only required data and minimizing communications overhead. Polling 32 channels from 100 sites requires
only 37,800 bytes per second of IP capacity at the central site, and only 378 bytes per second at each remote site.
If communications bandwidth is at a premium cost, it can be further reduced by selection of a slower poling rate.
MACRO PRESETS
To set up the preset numbers used to identify macros during an
RSI session, open the
ESI Macro Presets
dialog from
Edit >
Settings > ESI Macro Presets…
and select macro names to be
associated with as many presets as desired.
Edit>Settings>ESI Macro Presets
SITE SPEECH LABEL
To assign the ARC Plus a speech label for site identification during an RSI session, choose
Set Site Name Speech
Labels…
from the
Tools
menu. Even if an RSI is not installed on a particular ARC Plus unit, assigning a speech label
allows other RSI units to identify the unit during an RSI session.
Edit>Settings>ESI Macro Presets