84
ANTENNA MONITOR
An older antenna monitor that has to be scanned for the phase and ratio readings can be read with a macro
like this. The antenna monitor phase and ratio are stored in separate channels for each tower. The values
are held until the next set of samples is taken. Tower strobes are set up as latches. The schedule for this
macro is set for interval.
1
Raise "TWR1 ON" on site "BURK-FM" for [default]
2
Wait for 00:00:05
3
Set 1 Phase on BURK-FM = MON PHASE on BURK-FM
4
Set 1 Ratio on BURK-FM = MON RATIO on BURK-FM
5
Lower "TWR1 OFF" on site "BURK-FM" for [default]
6
Raise "TWR2 ON" on site "BURK-FM" for [default]
7
Wait for 00:00:05
8
Set 2 Phase on BURK-FM = MON PHASE on BURK-FM
9
Set 2 Ratio on BURK-FM = MON RATIO on BURK-FM
10
Lower "TWR1 OFF" on site "BURK-FM" for [default]
11
End macro