BURG WATCHER secuENTRY Скачать руководство пользователя страница 4

secuENTRY

English | 4 

ENTRY Fingerprint

General information

 

The electronic cylinder is operated using a scanned finger. Up to 24 fingers 

can be programmed using the keypad. The users are created separately 

(USER XXX_FP). If a code and/or an transponder should be additionally 

assigned to a user, it is to be created separately. Additionally, the lock 
can also be operated using a PIN code, the BURG-WÄCHTER KeyApp or a 
transponder.

Contents of the delivery 

1

 QR code keypad

11

 Rubber shell

2

 keypad

12

 Assembly aid

3

 Adapter set

13

 Disconnecting pliers

4

 Inner knob

14

 Tx (size 8)

5

 QR code Transponder

15

 Forend screw

6

 Transponder

16

 Allen key (size 3)

7

  Fixing materials 1 keypad 

17

 QR-Code Zylinder

18

 Cylinder

8

  Fixing materials 2 keypad (adhesive 

pads)

19

 Wall mounting plate

20

 Sight protection film

9

 Cylinder extension

10

 Adapter screws

Attention! The fingerprint sensor must not be cleaned with 
detergents. Please use a slightly moistened cloth for this purpose.

Functions:

• Total number of users: up to 50, out of whom number of fingerprints: up 

to 24

•  A transponder can also be assigned to every PIN code user (except 

administrator)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

17

5

2

8

9

11

15

16

12

13

20

19

6

3

7

10

14

18

4

ENTRY Basic

General information

 

The electronic cylinder is operated using a transponder. The transponder 
should be positioned in front of the cylinder knob.

Subsequent programming of additional transponders can be done using 

a secuENTRY keypad or the ENTRY software. The operating range of a 
transponder is up to 1 cm.

Contents of the delivery

1

 Adapter set

11

 Assembly aid

2

 Inner knob

12

 Disconnecting pliers

3

 QR code transponder 1

13

 Rubber shell

4

 Transponder 1

14

 QR code cylinder

5

 QR code transponder 2

15

 Cylinder

6

 Transponder 2

7

 Cylinder extension

8

  Adapter screws

9

 Allen key

10

 Forend screw

Functions

• Total number of users: up to 50

Optional locking media:
• ENTRY KP PIN

• ENTRY KP FP (up to 24 fingerprints possible)

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

14

13

10

9

11

12

5

6

3

1

15

2

8

7

4

Basic indication of the menu functions

When the “Func:M” symbol is displayed, the menu can be reached by 
pressing the “FUNC” key. In the menu, the keys “1” and “2” can be used 

as a scroll function to navigate through the menu structure. The  (Enter) key 

can be used to reach the next menu level.

Structure of the menu 

Code change menu
Sprache/Language menu
Administrator menu
 

Create user menu

 

 

Create: Code

 

 

Create: Transponder

 

 

Create: Fingerprint

 

Assign transponder menu

 

Delete menu

 

Additional functions menu

 

 

Date adjustment   not available in the standard version

 

 

Time adjustment => not available in the standard version

 

Setup menu

  

Register

  

Reorganise

 

FP reset menu

Info menu

Description of the menu

The following text described the functions for the products 

ENTRY Pincode

 

and 

ENTRY Fingerprint.

Menu Code change

 

Changing the administrator code and the user codes

• Activate the keypad using the    key
•  Then press FUNC  

'Menu/Code Change' is 

• Confirm your selection using  

 

•  Now you can use the keys 1 or 2 to scroll until the administrator / user, 

whose user code should be changed, is displayed

• Confirm with  
• Enter the code valid so far (existing code) and press  
• Enter the new code and confirm it with  
•  Repeat your entry and confirm it again with  

.  

“Code change accomplished” is displayed after a correct entry

Содержание secuENTRY

Страница 1: ... Altenhofer Weg 15 58300 Wetter Germany Elctronic door Lock ENTRY Pincode ENTRY Fingerprint ENTRY Basic Pincode Fingerprint Basic www burg biz BA MA secuENTRY dp sds 03 2016 Innovative door acess safely and easily controlled via your smartphone ...

Страница 2: ...h on a protected data carrier Examples of additional functions using the optional ENTRY 5750 software User administration Assignment of authorisations History function Power supply 2 x MIGNON LR6 AA ALKALINE for the keypad 1 x lithium battery CR123A for the cylinder Illustration On key Activation of the keypad for the entry of opening code Enter key Selection of a menu item Function key The functi...

Страница 3: ...Turn the cylinder knob Opening with transponder Hold the transponder from the front at no more than 1 cm from the cylinder knob The LED integrated in the cylinder flashes once when the opening is successful Turn the cylinder knob Bitte beachten Sie dass die Tastatur bei dem Öffnungsvorgang mit einem Transponder vorher nicht über die Taste eingeschaltet werden darf Opening with fingerprint Schalten...

Страница 4: ... the delivery 1 Adapter set 11 Assembly aid 2 Inner knob 12 Disconnecting pliers 3 QR code transponder 1 13 Rubber shell 4 Transponder 1 14 QR code cylinder 5 QR code transponder 2 15 Cylinder 6 Transponder 2 7 Cylinder extension 8 Adapter screws 9 Allen key 10 Forend screw Functions Total number of users up to 50 Optional locking media ENTRY KP PIN ENTRY KP FP up to 24 fingerprints possible 14 13...

Страница 5: ...pad using the key Then press FUNC Menu Code Change is displayed Scroll using the 2 key till reaching the Administrator menu Confirm with Scroll using the 2 key till reaching the Delete item Enter the administrator code in order to acquire the authorisation for programming Scroll till reaching the user or the identification medium transponder you wish to delete and confirm your selection 2 with Dat...

Страница 6: ... x 30 M4 x 35 M4 x 40 M4 x 45 Tab 1 Required adapters Attention Attention shall be paid to prevent the inner knob from being bumped as the knob can break in such case The lock shall not be greased or oiled Proceed as follows to assemble the system Attach the cylinder to the door in order to determine whether an adapter is required Alternatively the door incl fittings can be measured dimensions A B...

Страница 7: ...der extension use a saw to shorten it to the required length and mount it back finally 10 Use the assembly aid to slide the cable through the outer knob Attention Do not pinch or damage the cable 11 Snap the adapter onto the cylinder 12Hold the cable tight and lead it through the nut Attention The cable must not overlap and must be completely stowed in the pocket 13 Use the attached Allen key to f...

Страница 8: ... sight protection film please proceed as follows Pour some water with a couple of drops of dishwashing detergent into a glass stir it cautiously free of foam and then use it to moisture gently the surface on which the film is to be applied Start pulling off the white protective sheet from 1 cm of film and straighten it out To change the position lift this surface carefully and attach it again as r...

Страница 9: ... power Warranty In order to be able to provide you with perfectly flawless and high quality products and an optimal support when you need servicing or repair we need you to present faulty or defective devices to your vendor together with a valid administrator code and the QR code s with the original purchase document attached When you return a device component based on your right of withdrawal fro...

Отзывы: