44
| English
secuENTR
secuENTRY easy
English
|
45
secuENTRY easy plus cylinder assembly
The installation of the secuENTRY easy plus cylinder is explained below.
Please read these assembly instructions carefully before installation.
Note:
The base size of the cylinder is 30 mm per side. The cylinder has a special
latching system on the inside and an adaptor set is included for the outer
knob, which enables you to use the cylinder for door thicknesses up to
119 mm (61/59, measured from the centre of the forend screw). No prior
adjustment is necessary. The appropriate screws are included with your set to
fit the adaptor lengths.
When delivered, the cylinder inner knob is completely closed (to the smallest
door thickness). Before you insert the cylinder into the door, you should
adjust it to your door thickness.
The inner knob is loosened and fixed by means of an integrated grub screw
in the rotary knob.
Attention! Never pull the inner knob completely off the shaft, as in
this case the electronics will be destroyed! The grub screw, which
ensures the catch on the shaft, may only be loosened slightly and
always remains in the plastic knob. The grub screw serves as a
pull-off protection!
Take care during assembly. Avoid impacts or sudden movements. The lock
should not be greased or oiled.
When installing the cylinder, proceed as follows:
1
Rough assessment of door thickness (incl. fittings)
2
Pull the outer knob off the shaft, move the inner knob over the locking
system (distances 2.85 mm) to the desired dimension.
Inner knob
30 mm adjustment range
Schematic diagram
Internal knob adjustment
3
Depending on the door thickness, you have the option of fitting adaptors
on the outside to improve the guidance of the emergency key.
All stored fingerprints are deleted; however, the corresponding users are
retained. Please select this menu and follow the instructions on the display in
case of repeated errors related to the use of fingerprints.
Info menu
Using this function, you can have several pieces of information of the
system displayed.
• Switch on the keypad using the key
• Then press
FUNC
; “Menu/Code Change“ appears
• Scroll using the 2 key until “Info menu” appears.
• Confirm with
.
• Using the 1 or 2 key, you can scroll between the following information:
- Version and serial number of the keypad
- Version and serial number of the cylinder
- Operating time of the cylinder
- Opening procedures of the cylinder
- Start-up date and time of the cylinder
Note:
For security reasons, complete information about the cylinder is only
displayed after entering a valid administrator code.