TROUBLESHOOTING
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems
encountered. If the problem remains after exhausting the troubleshooting steps, contact the Bunn-O-Matic
Technical Service Department.
•
Inspection, testing, and repair of electrical equipment should be performed only by qualified service personnel.
•
All electronic components have 120 volt ac and low voltage dc potential on their terminals. Shorting of
terminals or the application of external voltages may result in board failure.
•
Intermittent operation of electronic circuit boards is unlikely. Board failure will normally be permanent. If an
intermittent condition is encountered, the cause will likely be a switch contact or a loose connection at a
terminal or crimp.
•
Solenoid removal requires interrupting the water supply to the valve. Damage may result if solenoids are
energized for more than ten minutes without a supply of water.
•
The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. This will help
to avoid twists and kinks in the tubing.
•
Make certain that all plumbing connections are sealed and electrical connections tight and isolated.
•
This brewer is heated at all times. Keep away from combustibles.
WARNING –
• Exercise extreme caution when servicing electrical equipment.
• Unplug the brewer when servicing, except when electrical tests are specified.
• Follow recommended service procedures
• Replace all protective shields or safety notices
PROBLEM
Brew cycle will not start (ST, STF,
STA & STFA)
PROBABLE CAUSE
1. No water
2. No power or incorrect voltage to
the brewer
REMEDY
Water lines and valves to the brewer
must be open.
(A1) Check the terminal block for
120 volts across the black and
white terminals on two wire 120
volt brewers.
(A2) Check the terminal block for
120 volts across the red and white
terminals and the black and white
terminal on three wire 120/240
volt brewers.
(A3) Check the terminal block for
200 volts on Model STFB brewers
or 240 volts on "A Series" brewers
across the red and black termi-
nals.
(A4) Check the terminal block for
100 volts on Model SDB brewers
across the white and black termi-
nals.
(B) Check circuit breakers or fuses.
29251 101598
Содержание S
Страница 3: ...Page 3 00656 0000 USER NOTICES Continued 00882 0000 02763 0000 02765 0000 02769 0000 29251 101598 ...
Страница 31: ...Page 31 29251 052500 ...
Страница 32: ...Page 32 29251 052500 ...
Страница 33: ...Page 33 29251 052500 ...
Страница 34: ...Page 34 29251 052500 ...
Страница 35: ...Page 35 29251 052500 ...
Страница 36: ...Page 36 29251 052500 ...
Страница 37: ...Page 37 29251 052500 ...
Страница 38: ...Page 38 29251 052500 ...
Страница 39: ...Page 39 29251 052500 ...
Страница 40: ...Page 40 29251 052500 ...
Страница 41: ...Page 41 29251 052500 ...
Страница 42: ...Page 42 29251 080400 ...
Страница 43: ...Page 43 29251 052500 ...
Страница 44: ......