SERVICE (cont.)
LIMIT THERMOSTAT
Location:
The limit thermostat is located on the rear of
tank assembly.
Test Procedures:
1.
Disconnect the brewer from the power source.
2.
Disconnect the blue and black wires from the
limit thermostat.
3.
Check for continuity across the limit thermostat
terminals with a ohmmeter.
If continuity is present as described, the limit thermo-
stat is operating properly. If continuity is not present
as described, replace the limit thermostat.
P1800
P1586
FIG. 4 LIMIT THERMOSTAT
FIG. 5 LIMIT THERMOSTAT TERMINALS
Removal and Replacement:
1.
Remove all wires from limit thermostat termi-
nals.
2.
Carefully slide the limit thermostat out from
under the retaining clip and remove limit thermo-
stat.
3.
Carefully slide the new limit thermostat into the
retaining clip.
4.
Refer to FIG. 5 when reconnecting the wires.
29251 052500
BLK to Tank
Heater Switch
BLK to BLU Lead from
Control Thermostat
Содержание S
Страница 3: ...Page 3 00656 0000 USER NOTICES Continued 00882 0000 02763 0000 02765 0000 02769 0000 29251 101598 ...
Страница 31: ...Page 31 29251 052500 ...
Страница 32: ...Page 32 29251 052500 ...
Страница 33: ...Page 33 29251 052500 ...
Страница 34: ...Page 34 29251 052500 ...
Страница 35: ...Page 35 29251 052500 ...
Страница 36: ...Page 36 29251 052500 ...
Страница 37: ...Page 37 29251 052500 ...
Страница 38: ...Page 38 29251 052500 ...
Страница 39: ...Page 39 29251 052500 ...
Страница 40: ...Page 40 29251 052500 ...
Страница 41: ...Page 41 29251 052500 ...
Страница 42: ...Page 42 29251 080400 ...
Страница 43: ...Page 43 29251 052500 ...
Страница 44: ......