SERVICE (cont.)
THERMAL CUT-OFF (Models SA, STA & STFA)
Location:
The thermal cutoffs are located on both tank
heater terminals.
Test Procedures:
1.
Disconnect the brewer from the power source.
2.
Disconnect the thermal cutoff from the tank
heater terminal and the limit thermostat or wir-
ing harness.
3.
Check for continuity across the thermal cutoff
terminals using an ohmmeter.
If continuity is present, the thermal cutoff is operating
properly. If continuity is not present as described,
replace the thermal fuse.
Removal and Replacement:
1.
Disconnect the thermal cutoff from the tank
heater terminal and the limit thermostat or wir-
ing harness.
2.
Remove thermal cutoff and discard.
3.
Connect new thermal cutoff to the tank heater
terminal and the limit thermostat or wiring har-
ness.
4.
Refer to FIG. 24 when reconnecting wires.
FIG. 24 THERMAL CUT-OFF
P1593
Thermal cutoff to BLK Lead
Thermal cutoff to WHI or RED Lead
29251 052500
Содержание S
Страница 3: ...Page 3 00656 0000 USER NOTICES Continued 00882 0000 02763 0000 02765 0000 02769 0000 29251 101598 ...
Страница 31: ...Page 31 29251 052500 ...
Страница 32: ...Page 32 29251 052500 ...
Страница 33: ...Page 33 29251 052500 ...
Страница 34: ...Page 34 29251 052500 ...
Страница 35: ...Page 35 29251 052500 ...
Страница 36: ...Page 36 29251 052500 ...
Страница 37: ...Page 37 29251 052500 ...
Страница 38: ...Page 38 29251 052500 ...
Страница 39: ...Page 39 29251 052500 ...
Страница 40: ...Page 40 29251 052500 ...
Страница 41: ...Page 41 29251 052500 ...
Страница 42: ...Page 42 29251 080400 ...
Страница 43: ...Page 43 29251 052500 ...
Страница 44: ......