Page 15
ON
OF
F
ST
AR
T
SERVICE (cont.)
LIMIT THERMOSTAT
Location:
The limit thermostat is located inside the hood on
the tank lid.
Test Procedures:
1. Disconnect the brewer from the power source.
2. Disconnect the blue/black and black wires from
the limit thermostat.
3. With an ohmmeter, check for continuity across the
limit thermostat terminals.
If continuity is present as described, the limit thermo-
stat is operating properly.
If continuity is not present as described, replace the
limit thermostat.
P2267
P1800
BLU/BLK Lead to
Control Thermo-
stat
BLK to Power
Cord or Terminal
Block Black Insert
27479 121500
Removal and Replacement:
1. Remove all wires from limit thermostat terminals.
2. Carefully slide the limit thermostat out from under
the retaining clip and remove limit thermostat.
3. Carefully slide the new limit thermostat into the
retaining clip.
4. Refer to Fig. 5 when reconnecting the wires.
FIG. 4 LIMIT THERMOSTAT
FIG. 5 LIMIT THERMOSTAT TERMINALS
All manuals and user guides at all-guides.com