background image

Page 19

ON

OF

F

ST

AR

T

TANK HEATER

Location:

The  tank  heater  is  located  inside  the  tank  and

secured to the tank lid.

Test Procedures:
1. Disconnect the brewer from the power supply.
2. With  a  voltmeter,  check  the  voltage  across  the

black and white wires on 120 volt models or the
black and red wires for 120/208 or 120/240 volt
models,  200  volt  models  and  240  volt  models.
Connect the brew to the power source. The indica-
tion must be:
a) 120 volts ac for  two  wire 120 volt models .
b) 208 volts ac for three wire 120/208 and 240
volts ac for three wire 120/240 volt models.
c) 200 to 240 volts ac for two wire 200 or 240 volt
models.

3. Disconnect the brewer from the power source.

If voltage is present as described, proceed to #4.
If  voltage  is  not  present  as  described,  refer  to  the

Wiring Diagrams

 and check wiring harness.

4. Disconnect the black wire and the white wire or red

wire from the tank heater terminals.

5. Check for continuity across the tank heater termi-

nals.

If continuity is present as described, reconnect the
wires, the tank heater is operating properly.
If continuity is not present as described, replace the
tank heater.

NOTE-

  If  the  tank  heater  remains  unable  to  heat,

remove and inspect heater for cracks in the sheath.

SERVICE (cont.)

P2267

P1176

27479 121500

FIG. 13 TANK HEATER TERMINALS

Removal and Replacement

1. Shut off water supply to the brewer.
2. Disconnect the water supply tubes on the tank lid

for the tank and the faucet coil assembly.

3. Disconnect the blue/black wire from the limit ther-

mostat to the control thermostat.

4. Disconnect the black wire and the white or red wire

from the tank heater terminals.

5. Remove sprayhead and the hex nut securing the

sprayhead tube to the hood.  Set aside for reas-
sembly.

6. Remove the eight #8-32 nuts securing the tank lid

to the tank.

7. Remove the tank lid with limit thermostat, spray-

head tube, tank heater and faucet coil assembly as
a assembly.

8

Remove the two hex nuts securing the tank heater
to the tank lid. Remove tank heater with gaskets
and discard.

10. Install new tank heater with gaskets on the tank lid

and secure with two hex nuts.

11. Install  tank  lid  with  limit  thermostat,  sprayhead

tube, tank heater and faucet coil assembly using
eight #8-32 hex nut.

12. Reconnect the inlet and outlet water lines to the

faucet coil assembly and the tank fill tube.

13. Secure spayhead tube to hood using a hex nut.
14. Install sprayhead.
15. Reconnect the wires to the limit thermostat, tank

heater and control thermostat. See limit thermo-
stat and control thermostat sections in this manual
when reconnecting wires.

16. Refer to Fig. 13 when reconnecting the tank heater

wires.

FIG. 12 TANK HEATER

All manuals and user guides at all-guides.com

Содержание GMB-PS

Страница 1: ...E D BO ILED DR Y HE AT ED WHE N EM PT Y US ED ON HIGH FL AM E OR EX PO SE D EL EC TR IC EL EM EN TS FA ILURE TO COMPL Y RISKS INJU RY PN 658 198 5 BU NN O MA TIC CO RP OR AT ION FU NNEL CONTE NTS ARE...

Страница 2: ...Y OR FITNESS FOR A PARTICULAR PURPOSE The agents dealers or employees of Bunn are not authorized to make modifications to this warranty or to make additional warranties that are binding on Bunn Accord...

Страница 3: ...ED ON HIGH FLAME OR EXPOSED ELECTRIC ELEMENTS READ THE ENTIRE OPERATING MANUAL BEFORE USING THIS PRODUCT FAILURE TO COMPLY RISKS INJURY PN 00658 0000F 6 98 1985 BUNN O MATIC CORPORATION 00831 0000F 3...

Страница 4: ...REQUIREMENTS This brewer must be connected to a cold water system with operating pressure between 20 and 90 psi 138 and620kPa froma1 2 orlargersupplyline Ashut offvalveshouldbeinstalledinthelinebefore...

Страница 5: ...opped flowing from the funnel and let the water in the tank reheat to the proper temperature 7 Placethe ON OFF switchinthe ON upperposition andmomentarilypressandreleasethestartswitch Check the water...

Страница 6: ...ng to be done until switch is once again placed in the SET position OPERATING CONTROLS ON OFF SWITCH Placing the ON OFF switch in the OFF lower position stops brewing Stopping a brew cycle after it ha...

Страница 7: ...edorloosened Thiswillhelp to avoid twists and kinks in the tubing Make certain that all plumbing connections are sealed and electrical connections tight and isolated This brewer is heated at all times...

Страница 8: ...ions Clear or replace A Direction of flow arrow must be pointing towards brewer B Removestrainerandcheckfor obstructions Clear or replace Refer to Service Limit Thermo stat for testing procedures See...

Страница 9: ...row must be pointing towards the brewer B Remove the flow control and check for obstructions Clear or replace A Direction of flow arrow must be pointing towards the brewer B Removethestrainerandcheck...

Страница 10: ...er condi tions Excessive mineral build up on stainless steel surfaces can ini tiate corrosive reactions resulting in serious leaks 3 Solenoid Valve 1 Timer REMEDY A Direction of flow arrow must be poi...

Страница 11: ...and clear any obstructions Rebuild or replace the valve if necessary See page 17 BUNN paperfiltersmustbeused for proper extraction A fine or drip grind must be used for proper extraction Aseven holest...

Страница 12: ...ofgroundsleveledbygentlyshak ing The nut on the solenoid must be tight or it will vibrate during op eration Plumbing lines should not resting on the counter top A Thebrewermustbeconnected to a cold wa...

Страница 13: ...Inspection testing and repair of electri cal equipment should be performed only by qualified service personnel The brewer should be unplugged when servicing except when electrical tests are re quired...

Страница 14: ...2267 P1171 27479 091596 to the power source The indication must be a 120 volts ac for two wire 120 volt models three wire 120 208 and 120 240 volt models b 200 to 240 volts ac for two wire 200 volt or...

Страница 15: ...s operating properly If continuity is not present as described replace the limit thermostat P2267 P1800 BLU BLK Lead to Control Thermo stat BLK to Power Cord or Terminal Block Black Insert 27479 12150...

Страница 16: ...rewer wiring har ness 5 With the black wire removed remove the white red wire from the lower terminal 6 Check for continuity across the center and lower terminal with the switch in the ON position Con...

Страница 17: ...noid valve for a clicking sound as the coil magnet attracts 7 Disconnect the brewer from the power source If the sound is heard as described and water will not pass through the solenoid valve there ma...

Страница 18: ...he white orange wire to the top terminal and the white yellow wire to the bottom terminal If continuity is not present as described replace the switch ON OF F ST AR T N operating pressure Control 2422...

Страница 19: ...P1176 27479 121500 FIG 13 TANK HEATER TERMINALS Removal and Replacement 1 Shut off water supply to the brewer 2 Disconnect the water supply tubes on the tank lid for the tank and the faucet coil asse...

Страница 20: ...d proceed to 7 If voltage is not present as described refer to Wiring Diagrams and check the brewer wiring harness MI NU TE S BU NN O M AT IC P N 26 20 12 0 VA C ON OF F ST AR T P1170 P1177 27479 1215...

Страница 21: ...r source and replace the timer 7 With a voltmeter check the voltage across termi nals TL1 and TL4 when the ON OFF switch is in the ON position Connectthebrewertothepower source and press the START swi...

Страница 22: ...d Place the ON OFF switch in the ON position press and hold the START switch until three distinct clicks are heard and then release the switch Failure to release the switch within two seconds after th...

Страница 23: ...Page 23 27479 091596 All manuals and user guides at all guides com...

Страница 24: ...Page 24 27479 091596 All manuals and user guides at all guides com...

Отзывы: