The sequence of bathes is:

Bath 1: Cleaner Conditioner

Bath 2: Pre-Dip

Advice: First use the pre-dip solution
for cleaning of tank 3. Fill in the pre-
dip solution into tank 3 overnight and
after that re-use it to fill tank 2:

Bath 3: Catalyst

To stir the bath, always

use a very

clean glass or plastic rod that you rinse
in bath 2 - never in water.

Bath 4: Intensifier

Bath 5: spare bath

This spare bath can be used e.g. for our
electroless tin plating (SUR-Tin) at
room temperature. If not in use, please
fill the tank with plain water to avoid
deformation of the PVC walls.

Bath 6: Copper plating

Fix both anodes to the anode holders,

use anode bags to cover anodes and
use the strings to form a knod so that
the bags are kept in place. Make up the
copper bath as per the appending Bath
Setup instructions.

Anode preparation:

For proper copper plating results it is
necessary to run the anodes under wor-
king conditions but with reduced cur-
rent of 1 A/dm². For that reason fix a
clean and well brushed PCB of 200 x
300 mm in a board holder. Then mount
the holder onto the agitation rod and
screw it carefully. Start air agitation.
Start mechanical bath agitation. Adjust
agitation speed to about value 4 on the
scale. Activate rectifier and adjust a
current of 1 A / dm² : 2 sides x 6 dm² x
1 A / dm² = 12 A. Run the bath accor-
ding to items 8 to 12 of the Plating
System Step 5 instructions.
copper bath solution are then ready for
use.

Rinse section:

The Compacta ABC unit is equipped
with a water saving triple cascade rinse
section: two cascading rinsing tanks
with overflowf ollowed by one fresh
water spray rinse tank .

Pre-rinse always in the bath with the
highest water level followed by the
one with the lower level. Last rinsing
step is fresh water spray rinse (activa-
ted by foot switch). It is highly im-
portant to clean not only the PCB but
also the board holder with every rin-
sing step in order to avoid contaminati-
on of the following treatment bathes.

Bungard Elektronik GmbH&Co KG· · Rilke Str. 1 · D-51570 Windeck
Tel 02292 5036 · Fax 6175 · [email protected]

Compacta L30

Instructions for use

Plating line

Page 5

Содержание Compacta L30

Страница 1: ...2 Safety warnings In your own interest pay attention to all safety warnings on the unit and in the operating instructions Follow the instructions on operation and use of the unit in every respect 3 Ventilation Wherever you put the unit always en sure there is sufficient ventilation An exhaust system may be necessary de pending on your local requirements 4 Heat and moisture To prevent fire or the r...

Страница 2: ...ation in the appropriatesafety data sheets Do not allow chemicals to go into the drain The unit must not be used in the residential area keep away from child ren 9 Appliance check Close the drain valves before filling the tanks Use the machine only when all tanks are filled with liquid Other wise damage of the heating elements and tanks will happen immediately Control the liquid level daily The te...

Страница 3: ...n and can be heated up to 70 C The second hea ter can be used up to 50 C 3 Electroplating tank Approx internal dimensions 400 x 275 x 400 mm D x W x H capacity approx 30l Draining by means of an attached tap in the bottom The tank is equipped with an air bubble pipe for liquid agitation 4 Control section Two thermostates with switch one air pump 400 l h with switch main switch 5 el Timer Conveyor ...

Страница 4: ...T Room temp Bath 3 Activator Catalyst RT Bath 4 Salt remover 45 C Bath 5 Sparebath Bath 6 Electroplate RT 3 3 Check if the heater switch lamp turns off automatically at preset tem perature 4 Check again after 4 5 hours if not hing is leeking 5 Startair agitation for plating bath 6 Start mechanical agitation and vary agitation speed 7 If all steps of this test are passed without problems switch off...

Страница 5: ... that reason fix a clean and well brushed PCB of 200 x 300 mm in a board holder Then mount the holder onto the agitation rod and screw it carefully Start air agitation Start mechanical bath agitation Adjust agitation speed to about value 4 on the scale Activate rectifier and adjust a current of 1 A dm 2 sides x 6 dm x 1 A dm 12 A Run the bath accor ding to items 8 to 12 of the Plating System Step ...

Страница 6: ... Note al low 0 05 to 0 1mm extra diameter for the drill bits because copper plating in the holes will reduce the effective diameter After that use one of our brushing ma chines RBM series for scrub clean ing washing and drying if no bru shing machine available brush and clean manually 3 Fix the cleaned and deburred board in the COMPACTA 3 finger board holder and fix it on the leftmost con veyour a...

Страница 7: ...ey can be easily replenis hed by simply adding the appropriate product See the instructions on the following Plating System Step descrip tions Missing replenishment will spoil Bath maintenance The Analysis procedures in the Plating System Step descriptions arefor expert use only This is to say the bathes maintain stable and working also wit hout analyses only by replenishment The Analysis procedur...

Страница 8: ......

Страница 9: ......

Отзывы: