background image

Equipment

System for through hole plating of
PCB. The conveyor arms are remova-
ble and adjustable.

1. Front Rinsing unit

Spraying system with spraying
nozzles, actuated by electromagnetic
foot switch valve, regulated by manual
valve (front-side right). Cascade sy-
stem with overflow for clean water
surface, actuated by the left manual
valve. Water dipping tank

Connect the unit with main fresh water
supply and drainage system before use.

In spite of the multiple rinsing tech-
nique the rinsing water contains metals
like copper, observe the local regulati-
ons.

2. Treatment tanks

Five treatment tanks, approx. internal
dimensions 300 x 100 x 400 mm (D x
W x H). Content approx. 10l. Draining
by means of a tap in the bottom. Two
tanks are equipped with PTFE coated
heating elements, 220 V 400 W, con-
trolled by thermostat. The first tank
has an insert of Polypropylen and can
be heated up to 70°C. The second hea-
ter can be used up to 50°C.

3. Electroplating tank

Approx. internal dimensions: 400 x
275 x 400 mm (D x W x H), capacity
approx. 30l. Draining by means of an
attached tap in the bottom. The tank is
equipped with an air bubble pipe for
liquid agitation.

4. Control section

Two thermostates with switch, one air
pump 400 l/h with switch, main
switch, 5 el. Timer, Conveyor poten-
tiometer and switch, rectifier adjusta-
ble up to 6 V 40 A and switch, internal
fuses.

Cleaning

The unit is made of PVC. Do not use
organic solvents to clean the machine.
A cloth is under normal conditions suf-
ficient for cleaning. For very resistant
dirt (for example baked on residues)
use sulphuric acid for tanks 1,4 and 6
or diluted hydrochloric acid for tanks 2
and 3. After cleaning the inner of tank
3 remove all cloth fuzzles and rinse the
tank walls and ground with deminera-
lized water.

Bungard Elektronik ·GmbH&Co KG· Rilke Str. 1 · D-51570 Windeck
Tel 02292 5036 · Fax 6175 · [email protected]

Compacta L30

Instructions for use

Plating line

Page 3

Содержание Compacta L30

Страница 1: ...2 Safety warnings In your own interest pay attention to all safety warnings on the unit and in the operating instructions Follow the instructions on operation and use of the unit in every respect 3 Ventilation Wherever you put the unit always en sure there is sufficient ventilation An exhaust system may be necessary de pending on your local requirements 4 Heat and moisture To prevent fire or the r...

Страница 2: ...ation in the appropriatesafety data sheets Do not allow chemicals to go into the drain The unit must not be used in the residential area keep away from child ren 9 Appliance check Close the drain valves before filling the tanks Use the machine only when all tanks are filled with liquid Other wise damage of the heating elements and tanks will happen immediately Control the liquid level daily The te...

Страница 3: ...n and can be heated up to 70 C The second hea ter can be used up to 50 C 3 Electroplating tank Approx internal dimensions 400 x 275 x 400 mm D x W x H capacity approx 30l Draining by means of an attached tap in the bottom The tank is equipped with an air bubble pipe for liquid agitation 4 Control section Two thermostates with switch one air pump 400 l h with switch main switch 5 el Timer Conveyor ...

Страница 4: ...T Room temp Bath 3 Activator Catalyst RT Bath 4 Salt remover 45 C Bath 5 Sparebath Bath 6 Electroplate RT 3 3 Check if the heater switch lamp turns off automatically at preset tem perature 4 Check again after 4 5 hours if not hing is leeking 5 Startair agitation for plating bath 6 Start mechanical agitation and vary agitation speed 7 If all steps of this test are passed without problems switch off...

Страница 5: ... that reason fix a clean and well brushed PCB of 200 x 300 mm in a board holder Then mount the holder onto the agitation rod and screw it carefully Start air agitation Start mechanical bath agitation Adjust agitation speed to about value 4 on the scale Activate rectifier and adjust a current of 1 A dm 2 sides x 6 dm x 1 A dm 12 A Run the bath accor ding to items 8 to 12 of the Plating System Step ...

Страница 6: ... Note al low 0 05 to 0 1mm extra diameter for the drill bits because copper plating in the holes will reduce the effective diameter After that use one of our brushing ma chines RBM series for scrub clean ing washing and drying if no bru shing machine available brush and clean manually 3 Fix the cleaned and deburred board in the COMPACTA 3 finger board holder and fix it on the leftmost con veyour a...

Страница 7: ...ey can be easily replenis hed by simply adding the appropriate product See the instructions on the following Plating System Step descrip tions Missing replenishment will spoil Bath maintenance The Analysis procedures in the Plating System Step descriptions arefor expert use only This is to say the bathes maintain stable and working also wit hout analyses only by replenishment The Analysis procedur...

Страница 8: ......

Страница 9: ......

Отзывы: