Problems with Express Setup
■
Following message appears when you try to install Express Setup to the hard disk
that has smaller capacity than the specified partition size:
“The specified partition size has exceeded the capacity of the hard disk. The setup
created the partition at the maximum size that can be reserved on the hard disk.
Setup will continue the process.”
Then the system displays the OK button.
- It is not an abnormal condition. Press Enter to continue the installation.
■
The message “Press R to retry” can not be displayed correctly when copying the
files from disc or checking disc:
- Press R. When the message appears again even if you press R, restart the
Express Setup from the beginning. In case the same result occurred after the
restart of installation, contact Maintenance Service Company and ask them to
check the disc drive.
■
Express Setup terminated and asks to input setup information.
- There are some errors on the specified setup information. Follow the instruction
to input the correct value. It is not necessary to cancel the installation.
■
Specified to join the Domain, but the system is installed as Workgroup.
- When the setup fails to join the Domain during the installation, it will install the
system as Workgroup. Open [System] in Control Panel to specify joining the
Domain.
■
Entered the incorrect Product ID/CD key.
- Even if you entered the incorrect Product ID/CD key, Express Setup will start.
However, the setup will stop and asks you to re-enter the correct value. Also in
this case, input request will occur when rebooting after GUI setup completed
during Express Setup. If these 2 inputs are done correctly, there is no problem
on Windows setup.
■
Unable to specify the details of Network adapter.
NvRAM access error
An access to the non-volatile memory (NvRAM)
has failed.
The system-specific information does not exist
on the baseboard. Please restore the backup
data or write the data by using [System
Information Management] of the Off-line
Maintenance Utility. Only the authorized
personnel are allowed to do this operation.
The system-specific information can't be
acquired on the mother board.
Table 14: Error Messages (Continued)
Message
Cause and Solution
Содержание NovaScale T840
Страница 1: ...NovaScale T840 User s Guide NOVASCALE REFERENCE 86 A1 97EV 01 ...
Страница 2: ......
Страница 11: ...User Guide 11 www bull com Specifications 290 Equipment Log 292 Hardware 293 Software 298 ...
Страница 187: ...User Guide 187 www bull com Figure 105 SAS Cable 1 to 4 A Backplane connector B Motherboard connectors ...
Страница 222: ...User Guide 222 www bull com Collecting the Memory Dump If applicable set to collect the memory dump debug information ...
Страница 283: ...User Guide 283 www bull com Error Manager Menu The Error Manager Menu displays any errors encountered during POST ...
Страница 301: ......
Страница 302: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 97EV 01 ...