User Guide
167
www.bull.com
4.
Unplug the processor fan cable from the server board.
5.
Loosen the four captive screws on the corners of the heat sink.
6.
Twist the heat sink slightly to break the seal between the heat sink and the
processor.
7.
Lift the heat sink from the processor.
Caution
If it does not pull up easily, twist the heat sink again. Do not
force the heat sink from the processor. Doing so could damage
the processor.
8.
Lift the processor lever.
Figure 83: Lifting the Processor Lever
9.
Raise the CPU load plate.
Push the rear tab with your finger tip (A) to bring the front end of the load plate up
slightly. Open the load plate as shown (B)
.
Figure 84: Raising the CPU Load Plate
AF000176
AF000177
A
B