2-21

Setup Procedure

12.Repeat Steps 10 and 11 for each domain.

13.Check the Operating System environment pre-installed on each domain.

14.Shut down each Operating System to power down the corresponding domain to the

stand-by mode.

15.Toggle the local / integrated console to the PAP unit display. 

INACTIVE 

is displayed in the

Domain State 

boxes and the 

Power ON 

button is accessible for each domain.

Note:

For further details about the 

Power ON

 

/ OFF 

sequences, see 

Powering ON a Domain

 and

Powering OFF a Domain

 in the 

User's Guide

.

Shutting Down / Restarting the Server

1. From the PAM home page, click 

File 

 Close 

to return to the Microsoft Windows desktop.

2. Shut down the PAP unit by selecting the 

Shut Down

 command in the Start Menu.

3. Request the Customer to turn the power supply circuit breakers OFF.

4. Request the Customer to turn the power supply circuit breakers ON.

The Platform Management Board (PMB) in each CSS module automatically powers up to
the standby mode (48V) and the Platform Administration Processor (PAP) unit
automatically boots Microsoft Windows

 

software.

Содержание NovaScale 5xx5

Страница 1: ...NovaScale 5xx5 Installation Guide NOVASCALE REFERENCE 86 A1 40EM 06...

Страница 2: ...BLANK...

Страница 3: ...NOVASCALE NovaScale 5xx5 Installation Guide September 2007 BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE REFERENCE 86 A1 40EM 06 Hardware...

Страница 4: ...dering Form also provided at the end of this book Trademarks and Acknowledgements We acknowledge the right of proprietors of trademarks mentioned in this book Intel and Itanium are registered trademar...

Страница 5: ...a Integrity and Verification xvi Waste Management xvi Environmental Standards xvii Climatic and Atmospheric Specifications xvii Electrical Specifications xvii Electromagnetic Compatibility xvii Protec...

Страница 6: ...Disk Rack 1 22 FDA 1x00 FC Extension Disk Rack 1 23 Ethernet Hub 1 24 USB Modem 1 24 NPort Server 1 24 Chapter 2 Setup Procedure 2 1 Accessing Server Components 2 2 Opening the Front Door 2 2 Closing...

Страница 7: ...rver to the Enterprise LAN 2 44 Connecting the USB Modem and External Devices 2 45 Connecting the USB Modem 2 45 Connecting External Storage Peripherals 2 45 Testing Network Connections 2 46 Testing A...

Страница 8: ...vi Installation Guide Index X 1...

Страница 9: ...23 Figure 20 Ethernet hub features 1 24 Figure 21 USB modem features 1 24 Figure 22 NPort Server features 1 24 Figure 23 Opening the front door 2 2 Figure 24 Integrated console example 2 3 Figure 25 P...

Страница 10: ...ontrol pane 2 47 Figure 50 Central Subsystem node 2 48 Figure 51 Launching Adaptec Storage Manager 2 51 Figure 52 Displaying PAP Unit disk configuration 2 52 Figure 53 Rebooting the PAP Unit 2 52 Figu...

Страница 11: ...to PAM features 2 50 Table 5 NovaScale 5085 Server specifications A 3 Table 6 NovaScale 5165 Server specifications A 5 Table 7 NovaScale 5245 Server specifications A 7 Table 8 NovaScale 5325 Server s...

Страница 12: ...x Installation Guide...

Страница 13: ...unpacking and inspection procedures Chapter 2 Setup Procedure explains the procedures required to set up and start the server for the first time Appendix A Specifications Appendix B Conversion Tables...

Страница 14: ...pport personnel PAM Help Message Guide 86 A7 32ER provides the complete collection of PAM Help Messages containing valuable troubleshooting information This guide is intended for use by qualified supp...

Страница 15: ...tional CSA 60950 Canada European Community EC Council Directives This product is in conformity with the protection requirements of the following EC Council Directives Electromagnetic Compatibility 200...

Страница 16: ...his equipment Unauthorized changes or modifications could void the user s authority to operate the equipment Any changes or modifications not expressly approved by the grantee of this device could voi...

Страница 17: ...shall be observed when connecting or disconnecting devices to the system DANGER The Customer is responsible for ensuring that the AC electricity supply is compliant with national and local recommendat...

Страница 18: ...ered to be hazardous The optical drive contains internally a Class 3B gallium arsenide laser that is nominally 30 milliwatts at 830 nanometers The design incorporates a combination of enclosures elect...

Страница 19: ...9 336 EEC EN55022 Class A Limit Radiated Conducted Emissions EN55024 ITE Specific Immunity Standard EN61000 4 2 ESD Immunity Level 2 Contact Discharge Level 3 Air Dis charge EN61000 4 3 Radiated Immun...

Страница 20: ...27 IEC 60068 2 31 IEC 60068 2 47 IEC 60068 2 64 IEC 60050 ISO 2041 ISO 5348 ISO 5344 ISO 8626 Operating Mode on levelers Sinusoidal vibrations Duration 1 sweep 1 octave mn 5 16 Hz range 0 25 mm peak 1...

Страница 21: ...9295 ISO 9296 IEC 61260 IEC 60651 Bull NovaScale 5xx5 Series Bull NovaScale 5xx5 Series IEC 61672 1 Bull NovaScale 4000 Series IEC 61672 2 Bull NovaScale 4000 Series Operating LwAd Acoustical Power 7...

Страница 22: ...xx Installation Guide...

Страница 23: ...erver cabinet s and accessories Store packing items Installing and Securing the Cabinet Step OK Position the cabinet s Secure the cabinet s into place Remove shipping brackets Inspecting the Server St...

Страница 24: ...ftware Check server status Test CSS module ring connexions Power up down the server domain s Shut down restart the server Completing PAP Unit Configuration and Operating System Setup Step OK Change th...

Страница 25: ...LAN and Connecting External Devices Step OK Connect the server to the Enterprise LAN Connect external peripherals storage modem Confirming Correct Installation Step OK Test network connections Test Au...

Страница 26: ...xxiv Installation Guide...

Страница 27: ...ures It includes the following topics Overview on page 1 2 General Recommendations on page 1 7 Unpacking the Server Cabinet on page 1 8 Inspecting the Server before Unloading the Cabinet on page 1 8 I...

Страница 28: ...sion servers are delivered rack mounted and ready to use in high or low cabinets Figure 1 Bull NovaScale Server cabinets Dynamic Partitioning Bull NovaScale Servers can be dynamically partitioned into...

Страница 29: ...performance computing capabilites Technical and scientific applications High Performance Computing HPC Business Intelligence Datawarehousing Datamining Large enterprise applications ERP CRM SCM Large...

Страница 30: ...DDR DIMMs The QBB communicates with the rest of the system the high speed bidirectional link Scalability Port Switches SPS located on the MSX Internal Peripheral Drawer IPD The Internal Peripheral Dr...

Страница 31: ...undancy Platform Administration Processor PAP Unit The PAP Unit hosts all server administration software in particular Platform Administration and Maintenance PAM software KVM Switch The KVM Switch al...

Страница 32: ...eeded to manage and maintain the server Domain configuration and resource allocation Alert or maintenance requests to the Customer Service Center Error logging Test Diagnostics suites The server is de...

Страница 33: ...that it reaches room temperature before powering up optimum operating temperature 22 C 3 C hygrometry 50 5 CAUTION It is mandatory for the server to be transported vertically Servers are extremely hea...

Страница 34: ...onfiguration may differ according to the version chosen CAUTION If the inspection indicates an unacceptable safety condition the condition must be corrected before powering up the server 1 Check that...

Страница 35: ...en Me First box Removing CSS Module Shipping Brackets 11 From the front of the cabinet loosen and remove the 2 shipping brackets on either side of the CSS module cabinet with the 8 mm hex wrench Figur...

Страница 36: ...ont cabinet frame and the two deep stoppers are installed on the rear cabinet frame 1 From the front of the cabinet align the 2 narrow stoppers A with the front of the frame and tighten into place Fig...

Страница 37: ...acceptable safety condition the condition must be corrected before powering up the server 1 Visually check internal cables for damage 2 Visually check system components for damage 3 Manually check int...

Страница 38: ...h 3 4xPCI X 2x PCI Express slots 2xInternal Peripheral Drawers each with 4 DVD ROM drive 2xInternal Peripheral Drawers each with 5 2xInternal SCSI RAID disks 6 USB port PMB board 7 2 or 4 DPS units 8...

Страница 39: ...lots Internal Peripheral Drawer with 4 DVD ROM drive Internal Peripheral Drawer with 5 2xInternal SCSI RAID disks 6 USB port PMB board 7 2 or 4 DPS units 8 2xQBB subsets 1 to 4 CPUs each Multicore CPU...

Страница 40: ...X 2x PCI Express slots Internal Peripheral Drawer with 4 DVD ROM drive Internal Peripheral Drawer with 5 2xInternal SCSI RAID disks 6 USB port PMB board 7 2 or 4 DPS units 8 2xQBB subsets 1 to 4 CPUs...

Страница 41: ...able including 8 U x 4 1 15 16 IO Box IOC with 2 IOL board legacy ports 8 U x 4 16 17 IO Box IOC with 3 4xPCI X 2x PCI Express slots 17 Internal Peripheral Drawer with 4 DVD ROM drive Internal Periphe...

Страница 42: ...ion Guide I O Cabinet 10 PAP unit with CD ROM writer FDD and 2 disks 1 U 13 2 PDU s with AC power cable 14 2 FC disks 3x2 U 18 KVM extender remote 1 U Figure 10 NovaScale 5325 Partitioned Servers comp...

Страница 43: ...server includes the following components CSS module on page 1 18 Integrated console on page 1 20 Integrated Platform Administration Processor PAP unit on page 1 19 Keyboard Video Mouse KVM switch on p...

Страница 44: ...4 SCSI RAID disks 1 DVD ROM drive 1 USB port Rear 1 or 2 IO Box es Input Output Board Compact Each IO Box can house 1 HPB PCI Hot Plug Board 6 hot plug 133 MHz PCI X and PCI Xpress slots 2 long 4 sho...

Страница 45: ...P unit is located in the center of a high cabinet or at the top of a low cabinet PAP Unit 1U 1 P4C 3 GHz PC 1 GB RAM 2 x 80 GB SATA disks RAID1 1 CD DVD ROM drive 1 1 FDD 2 serial ports 1 parallel por...

Страница 46: ...of a high cabinet or at the top of a low cabinet The inegrated console contains the keyboard monitor and touch pad used for local access to the server and to the Platform Administration Processor PAP...

Страница 47: ...or the local server and the local Platform Administration and Maintenance console 8 Port KVM Switch Or Or 8 ports 1 power cable Figure 14 8 port KVM switch features 16 Port KVM Switch 16 ports 1 power...

Страница 48: ...2 RAID 1 1 spare 2 power cables redundant power supply Figure 17 FDA 1x00 FC disk rack features FDA 2x00 FC Disk Rack Optionally the FDA 2x00 FC Disk Rack is delivered with pre installed system disks...

Страница 49: ...k The FDA 1x00 FC Extension Disk Rack offers15 empty slots for data disks According to version the Disk Rack is located in the main or I O cabinet 15 slots 2 power cables redundant power supply Figure...

Страница 50: ...Modem The optional USB modem is used to transmit Autocalls to the Remote Maintenance Center if the Customer s maintenance contract includes the Autocall feature USB Modem 1 USB cable 1 RJ11 cable Fig...

Страница 51: ...leting PAP Unit Configuration on page 2 24 Configuring Customer Information on page 2 29 Configuring Autocalls on page 2 30 Connecting the PAP Unit to the Customer s Enterprise LAN on page 2 32 Connec...

Страница 52: ...net key Figure 23 Opening the front door 1 Unlock the front door with the key 2 Pull out the locking mechanism and turn to open 3 Open the door as required Closing the Front Door 1 Close the door 2 Tu...

Страница 53: ...ed console example To open the integrated console 1 Slide the console forward until it clicks into place 2 Use the front bar to lift the screen panel into position To close the integrated console 1 Pr...

Страница 54: ...figuration Each PMB is equipped with two code wheels used to identify each Central Subsystem and each CSS module in the Customer s configuration These code wheels are set prior to shipping factory def...

Страница 55: ...lity to ensure that the outlet is correctly wired and grounded to prevent an electrical shock Use one hand when possible to connect or disconnect signal cables to prevent a possible shock from touchin...

Страница 56: ...is an external application running on the Platform Administration Processor PAP unit under Microsoft Windows You will use the secured PAM Web based interface to operate monitor and configure the serv...

Страница 57: ...prompted request the Customer Administrator to enter the default User Name and Password Customer Administrator User Name Administrator Password administrator The PAM home page appears Note The PAM tr...

Страница 58: ...three areas in the browser window a Status pane a PAM Tree pane and a Control pane A Status pane on page 2 9 B PAM Tree pane on page 2 10 C Control pane on page 2 9 Figure 26 PAM user interface Note...

Страница 59: ...atus icon is green Event Messages shows the number and maximum severity of pending event messages CSS Availability Status if the CSS Module PMB is detected as present is configured correctly and is re...

Страница 60: ...links The following figure represents the status bar for a bi module server One CSS Module PMB is detected as PRESENT and the other is detected as ABSENT A Bar red CSS Module_0 not available Figure 2...

Страница 61: ...AM Tree is used to refresh expand or collapse the tree display Toolbar Buttons Explanation Refresh rebuild the PAM Tree to view changes Expand the complete tree Collapse the complete tree Expand selec...

Страница 62: ...ver Domain N A NovaScale 5xx5 Partitioned Server 16 port KVM Switch Console Display Domain Port 1 PAP Unit N A Port 2 CSS0 Mod0 IO0 MyOperations xx 1 Port 3 CSS0 Mod0 IO1 MyOperations xx 2 Port 4 CSS0...

Страница 63: ...factory scheme This test does NOT check XSP data link functional status XSP data link functional status is checked during the Power on sequence Step 19 Global XSP links test This test cannot be perfo...

Страница 64: ...click Advanced to open the Advanced Properties dialog Figure 32 Advanced properties dialog 8 Select the Ring Test check box and click Save An information message informs you that settings have been sa...

Страница 65: ...all tested ring connections are correct OK is displayed if at least one tested ring connection is incorrect KO is displayed The system functional status icon turns RED open the Domain Fault List for...

Страница 66: ...atus bar green in the Status pane the server domain can be powered up Note If an error dialog box appears during these sequences see Managing Domains in the User s Guide To power up down server domain...

Страница 67: ...server all servers can be powered on simultaneously as follows a Click Multiple Power The Multiple Power Domains On Off dialog opens b Click Power On All Execute to power on the servers and associated...

Страница 68: ...x containing up to eight domains MyOperations xx 1 MyOperations xx 2 MyOperations xx 3 MyOperations xx 4 MyOperations xx 5 MyOperations xx6 MyOperations xx7 MyOperations xx 8 This default scheme allow...

Страница 69: ...ne You are invited to load a Domain Scheme 2 Click Schemes The Schemes List dialog opens displaying the pre configured scheme 3 Select MyOperationsScheme and click Apply Figure 35 Domain schemes list...

Страница 70: ...and click Power On to power up the domain and associated hardware components Repeat this step for each domain in the Control pane 7 Follow the power on steps displayed in the Domain State boxes until...

Страница 71: ...Power ON OFF sequences see Powering ON a Domain and Powering OFF a Domain in the User s Guide Shutting Down Restarting the Server 1 From the PAM home page click File Close to return to the Microsoft W...

Страница 72: ...Start Programs NEC Storage Manager Server Setting Utility 2 Select the Users tab The default User Name and User Level is displayed in the User List Default User Name Administrator Default User Level...

Страница 73: ...IT the Customer is advised to replace the factory default sanadmin User Password Note The default sanadmin User Name CANNOT be changed To change the S N IT sanadmin User Password 1 From the PAP Unit...

Страница 74: ...es Network Identification Properties 8 Complete the fields as required Launching the PAP Configuration Setup Wizard To complete PAP unit configuration 1 Request the Customer to provide the Installatio...

Страница 75: ...The Release Type dialog opens Figure 40 Release type dialog 5 Check that the release type is correct NovaScale 5xx5 Servers The MonoDomain radio button must be highlighted NovaScale 5xx5 Partitioned...

Страница 76: ...ustomer Enterprise LAN settings and to change the default factory PAP unit network setting Figure 41 Network configuration dialog b Click the Change Windows Administrator Password button to change the...

Страница 77: ...uration via Web site dialog d Click the Configure SAN Software Identities button to change the default S N IT password and the ISM user name and password Figure 44 SAN software identities configuratio...

Страница 78: ...ous and must not be performed until the server has been fully tested If the Customer wants to rename the Central Subsystem this entails removing the existing Central Subsystem and adding a new Central...

Страница 79: ...complete Customer Service Engineer Intervention Reports to configure the Email server used to send messages via the e mail channel See Creating an E mail Server in the User s Guide To configure Custom...

Страница 80: ...Select the Enable Autocalls checkbox 4 Select the Send Heartbeat checkbox and enter a value in days for the autocall channel control in the Period box Recommended value 1 5 Select the autocall dispat...

Страница 81: ...a From the PAP Unit Microsoft Windows desktop configure the dial up connection Control Panel Phone and Modem Options b From the PAM Autocalls Control Pane select the Use modem connection checkbox c U...

Страница 82: ...s Enterprise LAN for remote platform administration and maintenance 1 Open the rear door and remove the left side cover 2 Guide the Enterprise network cable supplied by the Customer through the cable...

Страница 83: ...e PAP installation procedure in the home page address field http PAPname pam where PAPname is the name allocated to PAP unit during setup c Save your changes and close Internet Explorer 2 Launch Inter...

Страница 84: ...the setup wizard which guides you through the iSM Client configuration procedure 3 When you are requested to select Setup Type click basic extended function Next 4 Once setup is complete launch iSM C...

Страница 85: ...vered with the system 24 hours before the scheduled installation date Note For further information about the server booting environment see Using EFI Utilities in the User s Guide To complete Operatin...

Страница 86: ...ntrol pane 2 Check Operating System type Microsoft Windows or Linux logo in the Domain Identities box 3 Locate the DVD Rom drive MyOperations 1 Module0 IPD0 4 Note the KVM port for the domain MyOperat...

Страница 87: ...isplay to the domain display See Toggling the Local Integrated Console Display on page 2 12 4 Check Regional Date Time and Time Zone settings under EFI 5 The setup wizard is launched automatically and...

Страница 88: ...terface page opens Check settings and click Save and Apply Return to network configuration f Click Routing and Gateways to open the Routing and Gateways configuration page Complete the required fields...

Страница 89: ...gh the menus c Click Network Basic Network Card Configuration d Select the required network card and click Configure e From the Network Address Setup page select the setup method and complete the requ...

Страница 90: ...ete setup on each domain 1 From the Customer Administrator PAM Tree click Domain Manager The pre installed domains are displayed in the Control pane 2 Check Operating System type for each domain Micro...

Страница 91: ...setup wizard is launched automatically and guides the Customer and the Customer Service Engineer through the setup completion procedure approximately 30 minutes Once setup is complete Microsoft Windo...

Страница 92: ...eways configuration page Complete the required fields with the data supplied by the Customer and click Save Return to network configuration g Click DNS Client to open the DNS Client Options configurat...

Страница 93: ...up page select the setup method and complete the required fields with the data supplied by the Customer f From the Details settings area click Host name and name server Complete the required fields an...

Страница 94: ...AN NovaScale 5xx5 Partitioned Servers 9 Locate the corresponding IOL board MyOperations 1 Module0 IOC0 IOL0 MyOperations 2 Module0 IOC1 IOL1 MyOperations 3 Module1 IOC0 IOL0 MyOperations 4 Module1 IOC...

Страница 95: ...e equipped with an RJ11 connector through the cable cut out at the base of the cabinet 3 Connect the modem cable to the line port on the rear of the USB modem See the Cabling Guide 86 A192ER Note Mode...

Страница 96: ...the PAM home page click Configuration Tasks Autocalls 2 Click the Test Autocall button in the toolbar A dialog appears to confirm that the autocall has been sent to the Remote Maintenance Center Compl...

Страница 97: ...n See Powering Up Down Server Domains on page 2 16 2 Click Configuration Tasks Central Subsystem The Central Subsystem control pane opens 3 Select the Central Subsystem and click Remove A dialog opens...

Страница 98: ...in the PAM tree under the Hardware Monitor node Central Subsystem 1 Functional status icon 2 CSS availability status bar 3 Central Subsystem Figure 50 Central Subsystem node 9 Check server status syst...

Страница 99: ...s Group CA This group is designed for customer representatives responsible for the overall management configuration and operation of the system Members of the Customer Administrator group are allowed...

Страница 100: ...ponents View current PAM Web site user information View PAM version information X X X X X X History Manager View system history files messages and fault lists Manually archive system history files Vie...

Страница 101: ...it and PAM software have been customized you should now initialize the backup disk In the event of disk failure or logical data corruption the backup disk can be easily used to repair the disk hard mi...

Страница 102: ...Flush caches by powering down the PAP Unit 5 Complete the Comment box with the reason for rebooting the PAP Unit as shown in the following figure A Figure 53 Rebooting the PAP Unit 6 Remove the right...

Страница 103: ...the PAP Unit by pressing the Power On switch A in the above figure 8 Wait for Windows ready and launch Adaptec Storage Manager 9 Insert the blank third disk and monitor the building process Figure 55...

Страница 104: ...mBackupData js and PamRestoreData js scripts are stored in the PAM Site Data directory on the PAP unit WinDrive Program Files BULL PAM PAMSiteData ReleaseData Utilities Backing Up PAM Configuration Fi...

Страница 105: ...2 55 Setup Procedure...

Страница 106: ...elease level of deployed releases is compatible Warning The script file stops and restarts the PAM application before restoring PAM configuration data To restore PAM configuration data 1 If required i...

Страница 107: ...s Appendix A Specifications NovaScale 5085 Server Specifications on page A 2 NovaScale 5165 Server Specifications on page A 4 NovaScale 5245 Server Specifications on page A 6 NovaScale 5325 Server Spe...

Страница 108: ...ervice Clearance Front Rear Side free side 150 cm 100 cm 100 cm Operating Limits Dry bulb temperature range Relative humidity non condensing Max wet bulb temperature Moisture content Pressure Elevatio...

Страница 109: ...are auto sensing and auto ranging Current draw Power consumption Thermal dissipation 11 A max at 200 VAC input 2400 VA per full CSS module 2400 W 8190 BTU per full CSS mod ule Europe Nominal voltage...

Страница 110: ...Depth 140 0 cm 55 1 in Weight max 430 kg 915 lb Service Clearance Front Rear Side free side 150 cm 100 cm 100 cm Operating Limits Dry bulb temperature range Relative humidity non condensing Max wet b...

Страница 111: ...e cabinet Electrical Specifications power supplies are auto sensing and auto ranging Current draw Power consumption Thermal dissipation 11 A max at 200 VAC input 2400 VA per full CSS module 2400 W 819...

Страница 112: ...range Relative humidity non condensing Max wet bulb temperature Moisture content Pressure Elevation 15 C to 30 C 59 F to 86 F Gradient 5 C h 41 F h 35 to 60 Gradient 5 h 24 C 75 2 F 0 019 kg water kg...

Страница 113: ...are auto sensing and auto ranging Current draw Power consumption Thermal dissipation 11 A max at 200 VAC input 2400 VA per full CSS module 2400 W 8190 BTU per full CSS module Europe Nominal voltage V...

Страница 114: ...range Relative humidity non condensing Max wet bulb temperature Moisture content Pressure Elevation 15 C to 30 C 59 F to 86 F Gradient 5 C h 41 F h 35 to 60 Gradient 5 h 24 C 75 2 F 0 019 kg water kg...

Страница 115: ...are auto sensing and auto ranging Current draw Power consumption Thermal dissipation 11 A max at 200 VAC input 2400 VA per full CSS module 2400 W 8190 BTU per full CSS module Europe Nominal voltage V...

Страница 116: ...A 10 Installation Guide...

Страница 117: ...al to metric conversion table Metric to Imperial 1 meter meter 3 3 feet 1 09 yd yards 1 centimeter cm 0 3937 inches 1 kilometer km 0 62 mi miles 1 gram g 0 04 oz ounces avdp 1 kilogram kg 2 2 lbs poun...

Страница 118: ...B 2 Installation Guide AZERTY QWERTY Keyboard Lookup Table Figure 56 AZERTY keyboard Figure 57 QWERTY keyboard...

Страница 119: ...be used in PAM identifiers Illegal Characters Accentuated letters Slash Backslash Double quote Simple quote Inverted comma Ampersand Plus Asterisk Percent Equal sign Less than sign Greater than sign...

Страница 120: ...Identity Name 16 Table 12 String length rules Registry Keys PAM obtains file paths via 2 registry keys ReleaseRoot Contains PAP application file paths DLL WEB pages models Two versions of PAM softwar...

Страница 121: ...bort condition BINIT Bus Initialization signal pin used to signal a global fatal machine check condition BIOS Basic Input Output System A program stored in flash EPROM or ROM that controls the system...

Страница 122: ...hardware DIB Device Interface Board The DIB provides the necessary electronics for the Internal Peripheral Drawer See IPD and Chained DIBs DIG64 Developer Interface Guide for IA64 DIM Code Device Ini...

Страница 123: ...e mail address for the EMAIL channel the name of a user group for the WEB channel the SNMP Manager IP address for the SNMP channel Event channel Defines how the Event Manager sends an event message An...

Страница 124: ...heir creator to the computer that acts as their server for everyone on the Internet It is also commonly used to download programs and other files from other servers FWH FirmWare Hub G GB GigaByte 1 07...

Страница 125: ...he exchange of data See Parallel Port and Serial Port Internal Disk Subsystem Disk subsystem housed inside the NovaScale Internal Peripheral Drawer IPD IOB Input Output Board The IOB connects up to 11...

Страница 126: ...storage cabinet LVDS Low Voltage Differential SCSI M MAESTRO Machine Administration Embedded Software Real Time Oriented Part of the PAM software package embedded on the PMB board MCA Machine Check Ab...

Страница 127: ...onal status are displayed in the PAM Tree pane See Status pane and Control pane PAP unit Platform Administration Processor unit The PC hosting all server administration software PAP application Platfo...

Страница 128: ...modules RJ45 8 contact regular jack RMC Remote Maintenance Console ROM Read Only Memory A type of memory device that is used to store the system BIOS code This code cannot be altered and is not lost w...

Страница 129: ...See FSS SRAM Static RAM A temporary storage area for data and programs This type of memory does not need to be refreshed but is lost when the system is powered off See NVRAM and RAM SSI Server System...

Страница 130: ...tem the history file is predefined by the PAM software and is visible only to an administrator or User the history file is created by an administrator and is visible to both an administrator and an op...

Страница 131: ...external 2 45 DIB chained 1 18 DIMMs 1 18 Disks 1 19 Domain power down 2 16 power up 2 16 DVD CD ROM drive 1 18 E Electrical safety xv Electromagnetic compatibility xvii Electrostatic discharges xviii...

Страница 132: ...19 Server configuring 2 47 domain 2 16 getting to know 1 12 inspecting 1 8 restarting 2 17 2 21 shutdown 2 17 2 21 Server components accessing 2 2 CD ROM drive 1 19 console 1 20 core unit 1 18 CSS mod...

Страница 133: ...System components DVD CD ROM drive 1 18 T Toolbar PAM 2 11 U USB modem connecting 2 45 USB ports 1 18 User group PAP 2 49 User interface PAM 2 8 V VGA port 1 18 W Writing rules illegal characters B 3...

Страница 134: ...X 4 Installation Guide...

Страница 135: ...ments will be promptly investigated by qualified technical personnel and action will be taken as required If you require a written reply please include your complete mailing address below NAME Date CO...

Страница 136: ..._ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _...

Страница 137: ...BLANK...

Страница 138: ...BULL CEDOC 357 AVENUE PATTON B P 20845 49008 ANGERS CEDEX 01 FRANCE 86 A1 40EM 06 REFERENCE...

Страница 139: ...ur obtenir les tiquettes Use the cut marks to get the labels 86 A1 40EM 06 NovaScale 5xx5 Installation Guide NOVASCALE 86 A1 40EM 06 NovaScale 5xx5 Installation Guide NOVASCALE 86 A1 40EM 06 NovaScale...

Страница 140: ......

Отзывы: