24
WWW.BBTA.COM.AU
BBT-BBQ-DC
SPECIFICATIONS
Model No
BBT-BBQ-DC
Test Point Pressure
2.75KPA
Total Nominal Gas Consumption
83.30 MJ/H
Nominal Gas Consumption
15.0 MJ/H Main Burner (x4)
11.0 MJ/H Side Burner
12.3 MJ/H Back Burner
Injector Size*
1.12 mm for Main Burner
0.94 mm for Side Burner
1.02 mm for Back Burner
AGA Approval Number
AGA 7129 G
Note:
• For use outdoors and in well ventilated areas.
• WARNING: Accessible parts may be very hot. Keep young children away.
• Read the instruction manual before using you genuine Bull BBQ.
• Close the valve of the gas cylinder or the regulator after use.
• DO NOT use this BBQ in an enclosed area as it can be dangerous.
• Always maintain a minimum of 1 metre clearance to combustible
materials at the rear and sides of the BBQ. DO NOT use your Bull BBQ
under overhead combustible surfaces.
(* Injector size is marked clearly on the burner valve)
IGNITION: Battery operated multi shot ignition unit (Battery not included)
IMPORTANT
Read the instructions carefully and be sure your BBQ is properly installed,
assembled and cared for. Failure to follow these instructions may result in
serious bodily injury and/or property damage.
If you have any questions concerning assembly or operation, consult your
dealer or LPG Gas Company.
NEVER store a spare cylinder under the BBQ shelves or inside the trolley
housing. Any LPG cylinder not attached to the BBQ for use should be stored
outdoors and well away from the appliance.