24
UPS function, power fail
The UPS function activates when the main power supply fails.
Detection takes place on / after: Power failure and resumption.
Battery pack needs to be charged. The battery will be charged when the main power switch is on, this is
indicated by the led in the front panel.
When the main power is off the battery will not be charged!
Be aware that it takes a few ours to recharge the battery’s when the machine is not used for a couple of
days.
1.
Time interval detection "POWERFAIL_DELAY" is set to 10sec.
2.
After about 10 seconds, a "POWERFAIL" popup appears on the screen
3.
The internal buffer is completed.
4.
The print is paused.
5.
The printer goes to Z = Z + 10mm
6.
The position is saved
7.
A power fail restore file is created.
8.
The Home screen status changes to "Powerfail!"
9.
Once the power is restored, the print head a bed will start heating. Once the current temperature >
target temperature-3 the print will continue. The print will automatically continue without any user
interaction needed.
10.
After the power returns, the printer deletes the powerfail restore file.
11.
If the battery is empty and power has not yet been restored the printer will shut down. Once you
reboot and press the print button in the home screen, you get a message: “powerfail has been
detected”. You have the option to continue the print in this menu. If you click “cancel”, the restore
file is deleted and continuing the failed print is no longer possible.
If the bed is cooled down to <40°C please check if the object is still stuck to the bed!
*Note : When printing from USB the print progress will be saved and after a power shutdown.
The print can be resumed from the user interface. Resuming the print is not possible from the
Builder web portal however!