Buffalo Tools GEN1000I Скачать руководство пользователя страница 6

   

6   

DESCRIPTION 

(1) Economy control switch 

(2) Engine switch 

(3) Fuel tank 

(4) Spark plug 

(5) Muffler 

(6) Carrying handle  

(7) Choke lever 

(8) AC pilot light 

(9) Overload indicator light  

(10) Oil warning light 

(11) Ground (earth) terminal 

(12) DC protector 

(13) DC receptacle 

(14) AC receptacle 

 

(16) Fuel filter 

(17) Fuel tank cap 

(18) Fuel pump 

(19) Recoil starter 

(20) Fuel cock 

(21) Oil filler cap 

 (22) Air filter cover 

 

 

   

   

   

   

   

   

   

   

   

   

This   

is a Gasoline Powered Invertor Generator

   that   offers   clean   power   for   

electronics. 

1

ENGINE SWITCH 

The engine switch controls the ignition system. 

To Start generator, turn POWER  switch ON. Then the 
engine can be started by sliding Choke lever to CHOKE  
then pull Recoil. Allow engine to run for a few seconds 
then slide the Choke Lever to OFF. 

To Stop generator, press POWER switch to STOP. The engine will not run. 

2

ECONOMY CONTROL SWITCH 

When the economy control switch is turned “ON”, the economy control unit controls the engine speed according to the connected 
load. The results are better fuel connection and less noise. (Turn OFF when using less voltage.) 

 

Содержание GEN1000I

Страница 1: ...460 9436 Monday Friday 8 AM 4 PM Central Time A copy of the sales receipt is required FOR CONSUMER USE ONLY NOT FOR PROFESSIONAL USE KEEP THIS MANUAL SALES RECEIPT APPLICABLE WARRANTY FOR FUTURE REFE...

Страница 2: ...ommended by the Customer Service Representative The warranty does not extend to generators damaged or affected by fuel contamination accidents neglect misuse unauthorized alterations use in an applica...

Страница 3: ...rator near open flame Do not smoke near this generator Always operate this generator on a firm level surface Gasoline is highly flammable and explosive Handling fuel can result in serious injury or bu...

Страница 4: ...ult circuit interrupter GFCI in highly conductive areas such as metal decking or steel work GFCIs are available in line with some extension cords Do not use this generator in wet conditions rain snow...

Страница 5: ...rical devices Promptly turn off any malfunctioning devices and disconnect them Do not operate an excessive number of electrical devices in excess of the wattage capacity of this generator Do not turn...

Страница 6: ...t offers clean power for electronics 1 ENGINE SWITCH The engine switch controls the ignition system To Start generator turn POWER switch ON Then the engine can be started by sliding Choke lever to CHO...

Страница 7: ...engine The generator AC output automatically resets when the engine is stopped and then restarted The overload indicator light may come on for a few seconds at first when using electric devices that r...

Страница 8: ...lever to the ON position 2 Turn the fuel tank cap air vent knob clockwise to the OPEN position Turn the engine switch to the ON or RUN position 3 Turn the choke lever to the Closed To Start position 4...

Страница 9: ...on PERIODIC MAINTENANCE MAINTENANCE CHART Regular maintenance is important for the best performance and safe operation Item Remarks Pre operation check daily Initial 1months or20Hr Every 3months or50H...

Страница 10: ...a level surface and warm up the engine for several minutes Then stop the engine and turn the fuel cock knob to OFF Turn the fuel tank cap air vent knob clockwise 2 Loosen the screws and remove the co...

Страница 11: ...scoloration and remove the carbon 3 Check the spark plug type and gap Standard Spark Plug CMR6A Spark Plug Gap 0 6 0 7 mm 0 024 0 028 in 4 Install the spark plug 5 Install the cover FUEL TANK FILTER 1...

Страница 12: ...restart Safety device DC to OFF Press to reset the DC protector STORAGE Long term storage of your machine will require some preventive procedures to guard against deterioration 1 DRAIN THE FUEL 1 Rem...

Страница 13: ...Fuel RegularAutomobileGasoline FueltankCapacity 0 55Gallon RatedContinuousOperation 6 3 hr 50 load Lubricatingoil SAE10W30 LubricatingoilCapacity 7 5ounce StartingSystem RecoilStarter Ignitionsystem C...

Страница 14: ...of use 3 Do not operate the engine at full load during the first 20 hours of operation 4 Read and follow the Maintenance Care section of this Generator manual STORAGE INSTRUCTIONS Long term storage of...

Страница 15: ...15 WIRING DIAGRAM...

Страница 16: ...16...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...20...

Страница 21: ...21...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...24...

Страница 25: ...25...

Страница 26: ...d for two years If any emissions related part on your small off road engine is defective the part will be repaired or replaced by Buffalo Corp Owner s Warranty Responsibility Asthesmalloff roadengineo...

Страница 27: ...at a warranty station at no charge to the owner Notwithstanding the provisions herein warranty services or repair will be provided at all of our distribution centers that are franchised to service th...

Страница 28: ...nkcase breather assembly including Breather connection tube 6 Fuel tank evaporative emissions control system including a Purge valves b Fuel cap Fuel tank d fuel lines for liquid fuel and fuel vapors...

Отзывы: