IMPORTANT SAFETY INSTRUCTIONS 

STOP! 

Before using this generator, if you have any questions regarding the hazard and safety notices listed in this manual and/or 

on this generator, call 1-866-460-9436, Monday - Friday, 8 AM - 4 PM Central Time. 

                                                                                     

 

Carbon Monoxide Gas:

 

When in operation, the exhaust from this generator contains poisonous carbon monoxide gas. 

Carbon monoxide gas is both odorless and colorless AND may be present even if you do not see or smell gas. Breathing this 
poison gas can lead to headaches, dizziness, drowsiness, loss of consciousness and eventually death.

 

• USE THIS GENERATOR ONLY OUTDOORS IN NON-CONFINED AREAS. DO NOT SECURE THE 
GENERATOR WITH A CHAIN OR ROPE, AS THIS WILL MAKE IT DIFFICULT TO MOVE IN AN EMERGENCY. 

• Keep at least several feet of clearance on all sides to allow proper ventilation for this generator. 

 

                                                                                     

 

Flammable Gasoline:

 

This generator may emit highly flammable and explosive gasoline vapors, which can cause severe 

burns or even death. A nearby open flame can lead to an explosion even if not directly in contact with gasoline.

 

• Do not operate this generator near open flame. 

• Do not smoke near this generator. 

• Always operate this generator on a firm, level surface. 

Gasoline is highly flammable and explosive. Handling fuel can result in serious injury or burns. 

• Always shut down this generator before refueling. Refuel in a well-ventilated area. Keep heat, sparks and flame 
away while refueling and away from the location where gasoline is stored. Never refuel indoors where gasoline 
fumes may reach flames and/or sparks. 

• Allow this generator to cool for at least 2 minutes before removing the fuel tank cap. Loosen the cap slowly to 
relieve pressure in the fuel tank. Avoid spilling fuel. 

• Do not fill the fuel tank above the upper limit line. Gasoline may expand during operation. Do not fill to the top of 
the tank. 

• Always check for spilled gasoline and immediately wipe it up before starting this generator. 

• Empty the fuel tank before storing or transporting this generator. 

• Always handle fuel outdoors. 

• Before transporting, turn the fuel valve to the “OFF” position and disconnect the spark plug. 

NOTE: DO NOT USE GASOLINE CONTAINING MORE THAN 10% ETHANOL (e10) 

 

                                                                                     

 

Usage:

 

Prolonged exposure to high noise levels can be hazardous to hearing. 

Always wear ANSI-approved hearing protection when 

operating or working around the generator when it is running.

 

 

Содержание GEN1000I

Страница 1: ...460 9436 Monday Friday 8 AM 4 PM Central Time A copy of the sales receipt is required FOR CONSUMER USE ONLY NOT FOR PROFESSIONAL USE KEEP THIS MANUAL SALES RECEIPT APPLICABLE WARRANTY FOR FUTURE REFE...

Страница 2: ...ommended by the Customer Service Representative The warranty does not extend to generators damaged or affected by fuel contamination accidents neglect misuse unauthorized alterations use in an applica...

Страница 3: ...rator near open flame Do not smoke near this generator Always operate this generator on a firm level surface Gasoline is highly flammable and explosive Handling fuel can result in serious injury or bu...

Страница 4: ...ult circuit interrupter GFCI in highly conductive areas such as metal decking or steel work GFCIs are available in line with some extension cords Do not use this generator in wet conditions rain snow...

Страница 5: ...rical devices Promptly turn off any malfunctioning devices and disconnect them Do not operate an excessive number of electrical devices in excess of the wattage capacity of this generator Do not turn...

Страница 6: ...t offers clean power for electronics 1 ENGINE SWITCH The engine switch controls the ignition system To Start generator turn POWER switch ON Then the engine can be started by sliding Choke lever to CHO...

Страница 7: ...engine The generator AC output automatically resets when the engine is stopped and then restarted The overload indicator light may come on for a few seconds at first when using electric devices that r...

Страница 8: ...lever to the ON position 2 Turn the fuel tank cap air vent knob clockwise to the OPEN position Turn the engine switch to the ON or RUN position 3 Turn the choke lever to the Closed To Start position 4...

Страница 9: ...on PERIODIC MAINTENANCE MAINTENANCE CHART Regular maintenance is important for the best performance and safe operation Item Remarks Pre operation check daily Initial 1months or20Hr Every 3months or50H...

Страница 10: ...a level surface and warm up the engine for several minutes Then stop the engine and turn the fuel cock knob to OFF Turn the fuel tank cap air vent knob clockwise 2 Loosen the screws and remove the co...

Страница 11: ...scoloration and remove the carbon 3 Check the spark plug type and gap Standard Spark Plug CMR6A Spark Plug Gap 0 6 0 7 mm 0 024 0 028 in 4 Install the spark plug 5 Install the cover FUEL TANK FILTER 1...

Страница 12: ...restart Safety device DC to OFF Press to reset the DC protector STORAGE Long term storage of your machine will require some preventive procedures to guard against deterioration 1 DRAIN THE FUEL 1 Rem...

Страница 13: ...Fuel RegularAutomobileGasoline FueltankCapacity 0 55Gallon RatedContinuousOperation 6 3 hr 50 load Lubricatingoil SAE10W30 LubricatingoilCapacity 7 5ounce StartingSystem RecoilStarter Ignitionsystem C...

Страница 14: ...of use 3 Do not operate the engine at full load during the first 20 hours of operation 4 Read and follow the Maintenance Care section of this Generator manual STORAGE INSTRUCTIONS Long term storage of...

Страница 15: ...15 WIRING DIAGRAM...

Страница 16: ...16...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...20...

Страница 21: ...21...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...24...

Страница 25: ...25...

Страница 26: ...d for two years If any emissions related part on your small off road engine is defective the part will be repaired or replaced by Buffalo Corp Owner s Warranty Responsibility Asthesmalloff roadengineo...

Страница 27: ...at a warranty station at no charge to the owner Notwithstanding the provisions herein warranty services or repair will be provided at all of our distribution centers that are franchised to service th...

Страница 28: ...nkcase breather assembly including Breather connection tube 6 Fuel tank evaporative emissions control system including a Purge valves b Fuel cap Fuel tank d fuel lines for liquid fuel and fuel vapors...

Отзывы: