FEATURES: 

• 

1000 Surge Output  /  800 Running Watts*          

• 120V Operation 
• 1.3 HP Engine, 4 Stroke , 5500 RPM 
• Displacement (CC): 40cc 
• Low Oil Shut Off 
• UL Listed Electrical Components 
• Engine Shut Off Switch 
• Power Outlets   
• Power Your Sensitive Electronics With Stable, Constant Voltage  
• 1-12V DC Outlet 
• 1-120V Outlets 
• 0.55 Gallon Max Capacity Gasoline Fuel Tank 
• Complies with EPA & CARB emissions   
• Decibel Rating < 56 db 0% load measured at 23 feet 
• Run time = 6.3 hrs @ 50% load Gasoline 
• Fuel Type: Unleaded Gasoline Only 87 rating or higher 
• This portable generator is not for use with gasoline/ ethanol blends with over 15% ethanol. Do not use E85 fuel. 
• If you are using a generator above sea level, the generator may not function properly because of air flow getting through the carburetor. 
• High Altitude Use: This generator is not recommended for high altitude use above 3,000 feet. 

 

2 YEAR LIMITED EMISSION-RELATED WARRANTY  

THIS ENGINE MEETS U.S. EPA EMISSION STANDARDS UNDER 40 CFR 1054.625 .The emission-related limited warranty is valid for two (2) 
years. Keep the purchase receipt and mail in the product registration card for proof of purchase. Buffalo Corp limits emission-related warranty 
repairs to authorized service centers for owners located within 100 miles of an authorized service center. For owners located more than 100 miles 
from an authorized service center, Buffalo Corp will, in its sole discretion, either pay for shipping costs to and from an authorized service center, 
provide for a service technician to come to the owner to make the warranty repair, or pay for the repair to be made at a local non-authorized 
service center. The provisions of this paragraph apply only for the contiguous states, excluding the states with high-altitude areas identified in 40 
CFR part 1068, Appendix III. 

To exercise this warranty, DO NOT RETURN TO RETAILER. Instead, call Customer Service toll free at 1-866-460-9436 (email address 
[email protected]) and you will be instructed on where to take the engine for warranty service. Take the generator and proof of purchase (your 
receipt) to the repair facility recommended by the Customer Service Representative. The warranty does not extend to generators damaged or 
affected by fuel contamination, accidents, neglect, misuse, unauthorized alterations, use in an application for which the product was not designed 
and any other modifications or abuse.  

1 YEAR LIMITED WARRANTY  (30 Day Limited for Commercial/Rental Purpose) 

Generators are warranted to be free from defects in materials and workmanship for a period of 1 YEAR from date of original purchase. Buffalo Corp. is not 

liable for any indirect, incidental or consequential damages from the sale or use of this product. Any implied warranties are limited to 1 YEAR as stated, or 

as otherwise stated, in this written limited warranty. Some states do not allow the exclusion or limitation of incidental or consequential damages. Some 

states do not allow limitation on the length of an implied warranty. Buffalo Corp will repair or replace, at its discretion, any part that is proven to be 

defective in materials or workmanship under normal use during the 1 YEAR warranty period. Warranty repairs or replacements will be made without charge 

for parts or labor. Parts replaced during warranty repairs will be considered as part of the original product and will have the same warranty period as the 

original product. This warranty gives you specific legal rights, and you may have other rights that vary state to state.

 

Notice Regarding Emissions: 

Engines   certified   to   comply   with   California   and   U.S.   EPA   emission   regulations   for   SORE   (Small   Off   Road   Equipment)   are   certified   to   operate   on   regular   unleaded   
gasoline   and   may   include   the   following   emission   control   systems:   Three-­‐Way   Catalyst   (TWC)   (if   equipped),   and   Engine   Modifications   (EM).   

Legal Requirements: 

Federal   and/or   State   Occupational   Safety   and   Health   Administration   (OSHA)   regulations,   local   codes,   and/or   ordinances   may   apply   to   the   intended   use   of   this   
generator.   Consult   a   qualified   electrician,   electrical   inspector,   and/or   the   local   agency   having   jurisdiction.   Some   areas   require   generators   to   be   registered   with   
local   utility   companies.   Additional   regulations   may   apply   if   this   generator   will   be   used   at   a   construction   site.

 

Included with this Generator: 

• DC connector wires for connecting 12 Volt   
  automotive-type batteries 
• Spark plug wrench 
• Screwdriver 

 

Содержание GEN1000I

Страница 1: ...460 9436 Monday Friday 8 AM 4 PM Central Time A copy of the sales receipt is required FOR CONSUMER USE ONLY NOT FOR PROFESSIONAL USE KEEP THIS MANUAL SALES RECEIPT APPLICABLE WARRANTY FOR FUTURE REFE...

Страница 2: ...ommended by the Customer Service Representative The warranty does not extend to generators damaged or affected by fuel contamination accidents neglect misuse unauthorized alterations use in an applica...

Страница 3: ...rator near open flame Do not smoke near this generator Always operate this generator on a firm level surface Gasoline is highly flammable and explosive Handling fuel can result in serious injury or bu...

Страница 4: ...ult circuit interrupter GFCI in highly conductive areas such as metal decking or steel work GFCIs are available in line with some extension cords Do not use this generator in wet conditions rain snow...

Страница 5: ...rical devices Promptly turn off any malfunctioning devices and disconnect them Do not operate an excessive number of electrical devices in excess of the wattage capacity of this generator Do not turn...

Страница 6: ...t offers clean power for electronics 1 ENGINE SWITCH The engine switch controls the ignition system To Start generator turn POWER switch ON Then the engine can be started by sliding Choke lever to CHO...

Страница 7: ...engine The generator AC output automatically resets when the engine is stopped and then restarted The overload indicator light may come on for a few seconds at first when using electric devices that r...

Страница 8: ...lever to the ON position 2 Turn the fuel tank cap air vent knob clockwise to the OPEN position Turn the engine switch to the ON or RUN position 3 Turn the choke lever to the Closed To Start position 4...

Страница 9: ...on PERIODIC MAINTENANCE MAINTENANCE CHART Regular maintenance is important for the best performance and safe operation Item Remarks Pre operation check daily Initial 1months or20Hr Every 3months or50H...

Страница 10: ...a level surface and warm up the engine for several minutes Then stop the engine and turn the fuel cock knob to OFF Turn the fuel tank cap air vent knob clockwise 2 Loosen the screws and remove the co...

Страница 11: ...scoloration and remove the carbon 3 Check the spark plug type and gap Standard Spark Plug CMR6A Spark Plug Gap 0 6 0 7 mm 0 024 0 028 in 4 Install the spark plug 5 Install the cover FUEL TANK FILTER 1...

Страница 12: ...restart Safety device DC to OFF Press to reset the DC protector STORAGE Long term storage of your machine will require some preventive procedures to guard against deterioration 1 DRAIN THE FUEL 1 Rem...

Страница 13: ...Fuel RegularAutomobileGasoline FueltankCapacity 0 55Gallon RatedContinuousOperation 6 3 hr 50 load Lubricatingoil SAE10W30 LubricatingoilCapacity 7 5ounce StartingSystem RecoilStarter Ignitionsystem C...

Страница 14: ...of use 3 Do not operate the engine at full load during the first 20 hours of operation 4 Read and follow the Maintenance Care section of this Generator manual STORAGE INSTRUCTIONS Long term storage of...

Страница 15: ...15 WIRING DIAGRAM...

Страница 16: ...16...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...20...

Страница 21: ...21...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...24...

Страница 25: ...25...

Страница 26: ...d for two years If any emissions related part on your small off road engine is defective the part will be repaired or replaced by Buffalo Corp Owner s Warranty Responsibility Asthesmalloff roadengineo...

Страница 27: ...at a warranty station at no charge to the owner Notwithstanding the provisions herein warranty services or repair will be provided at all of our distribution centers that are franchised to service th...

Страница 28: ...nkcase breather assembly including Breather connection tube 6 Fuel tank evaporative emissions control system including a Purge valves b Fuel cap Fuel tank d fuel lines for liquid fuel and fuel vapors...

Отзывы: