Buffalo Tools GEN1000I Скачать руководство пользователя страница 4

   

4   

 

                                                                                     

 

Powerful Voltage:

 

This generator produces powerful voltage, which can result in electrocution.

 

• ALWAYS ground this generator before using it. (See “Ground the Generator” section in this manual). 

• Only electrical devices should be plugged into this generator, either directly or with an extension cord. NEVER 
connect a building electrical system to this generator without a qualified electrician. 

Doing so voids your warranty. 

 

Such connections must isolate generator power from utility power and comply with local electrical laws and codes. 
Failure to comply can create a back feed into utility lines creating an electrocution hazard, which may result in 
serious injury or death to utility workers. Such a back feed may cause this generator to explode, burn and create 
fires when utility power is restored. 

• Use a ground fault circuit interrupter (GFCI) in highly conductive areas such as metal decking or steel work. 
GFCIs are available in-line with some extension cords. 

• Do not use this generator in wet conditions (rain, snow, active sprinkler system, wet hands, etc.). Always keep 
this generator dry and operate it with dry hands. 

• Do not allow children or non-qualified persons to operate this generator. 

  

 

 

 

 

 

 

 

 

                                                                                       

 

 

High Temperatures:

 

This generator produces heat when in operation. Temperatures near the exhaust can exceed 150 Degrees 

Fahrenheit (65 Degrees Celsius).

 

• Do not touch hot surfaces. Observe all warning placards on this generator denoting hot surfaces. 

• Allow this generator to cool for several minutes after use before touching the engine, muffler or other areas that 
are hot during operation and before storing indoors. 

• Hot exhaust may ignite some materials. Keep flammable materials away from this generator. 

• Keep at least several feet of clearance on all sides of this generator during operation. Do not enclose this 
generator in any structure. 

Содержание GEN1000I

Страница 1: ...460 9436 Monday Friday 8 AM 4 PM Central Time A copy of the sales receipt is required FOR CONSUMER USE ONLY NOT FOR PROFESSIONAL USE KEEP THIS MANUAL SALES RECEIPT APPLICABLE WARRANTY FOR FUTURE REFE...

Страница 2: ...ommended by the Customer Service Representative The warranty does not extend to generators damaged or affected by fuel contamination accidents neglect misuse unauthorized alterations use in an applica...

Страница 3: ...rator near open flame Do not smoke near this generator Always operate this generator on a firm level surface Gasoline is highly flammable and explosive Handling fuel can result in serious injury or bu...

Страница 4: ...ult circuit interrupter GFCI in highly conductive areas such as metal decking or steel work GFCIs are available in line with some extension cords Do not use this generator in wet conditions rain snow...

Страница 5: ...rical devices Promptly turn off any malfunctioning devices and disconnect them Do not operate an excessive number of electrical devices in excess of the wattage capacity of this generator Do not turn...

Страница 6: ...t offers clean power for electronics 1 ENGINE SWITCH The engine switch controls the ignition system To Start generator turn POWER switch ON Then the engine can be started by sliding Choke lever to CHO...

Страница 7: ...engine The generator AC output automatically resets when the engine is stopped and then restarted The overload indicator light may come on for a few seconds at first when using electric devices that r...

Страница 8: ...lever to the ON position 2 Turn the fuel tank cap air vent knob clockwise to the OPEN position Turn the engine switch to the ON or RUN position 3 Turn the choke lever to the Closed To Start position 4...

Страница 9: ...on PERIODIC MAINTENANCE MAINTENANCE CHART Regular maintenance is important for the best performance and safe operation Item Remarks Pre operation check daily Initial 1months or20Hr Every 3months or50H...

Страница 10: ...a level surface and warm up the engine for several minutes Then stop the engine and turn the fuel cock knob to OFF Turn the fuel tank cap air vent knob clockwise 2 Loosen the screws and remove the co...

Страница 11: ...scoloration and remove the carbon 3 Check the spark plug type and gap Standard Spark Plug CMR6A Spark Plug Gap 0 6 0 7 mm 0 024 0 028 in 4 Install the spark plug 5 Install the cover FUEL TANK FILTER 1...

Страница 12: ...restart Safety device DC to OFF Press to reset the DC protector STORAGE Long term storage of your machine will require some preventive procedures to guard against deterioration 1 DRAIN THE FUEL 1 Rem...

Страница 13: ...Fuel RegularAutomobileGasoline FueltankCapacity 0 55Gallon RatedContinuousOperation 6 3 hr 50 load Lubricatingoil SAE10W30 LubricatingoilCapacity 7 5ounce StartingSystem RecoilStarter Ignitionsystem C...

Страница 14: ...of use 3 Do not operate the engine at full load during the first 20 hours of operation 4 Read and follow the Maintenance Care section of this Generator manual STORAGE INSTRUCTIONS Long term storage of...

Страница 15: ...15 WIRING DIAGRAM...

Страница 16: ...16...

Страница 17: ...17...

Страница 18: ...18...

Страница 19: ...19...

Страница 20: ...20...

Страница 21: ...21...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...24...

Страница 25: ...25...

Страница 26: ...d for two years If any emissions related part on your small off road engine is defective the part will be repaired or replaced by Buffalo Corp Owner s Warranty Responsibility Asthesmalloff roadengineo...

Страница 27: ...at a warranty station at no charge to the owner Notwithstanding the provisions herein warranty services or repair will be provided at all of our distribution centers that are franchised to service th...

Страница 28: ...nkcase breather assembly including Breather connection tube 6 Fuel tank evaporative emissions control system including a Purge valves b Fuel cap Fuel tank d fuel lines for liquid fuel and fuel vapors...

Отзывы: