2004 Buell P3: Electrical
7-9
HOME
Figure 7-7. Continuous or No Spark At Spark Plug
YES
NO
Is bank angle sensor connected?
Reconnect.
Disconnect connector [134].
Measure voltage on [134B] between socket A, LT GN/GY and socket B, BK
3.0-3.5 VDC
11-13 VDC
0 VDC
See next page
Repair short on
LT GN/GY wire.
5007
YES
NO
Repair open in
LT GN/GY wire.
5007
Disconnect connector [10]. Check continuity between socket A, LT GN/GY on
connector [134B] and socket 5, LT GN/GY on connector [10B].
Continuity present?
YES
NO
Check starter
interlock.
Check continuity to ground on LT GN/GY wire, socket A,
connector [134B] or [10B].
Is continuity present?
5007
Check continuity to ground on TN/Y wire, socket B,
connector [134B].
Is continuity present?
YES
NO
Inspect module harness
for damage.
Repair if necessary.
If harness is not damaged,
replace ignition module.
Repair short to ground on LT
GN/GY wire.
5007
*
To avoid damage to terminals, remove Bank
Angle Sensor before disconnecting connector [134].
Use HARNESS CONNECTOR ADAPTER KIT
HD-41404,Gray male probe and patch cord
Bank Angle Sensor
Connector [134]
8261
Содержание Blast 2014
Страница 2: ...1 2 Edit Me Printed June 19 2003 1 24 pm ...
Страница 39: ...1 8 2004 Buell P3 Maintenance HOME NOTES ...
Страница 77: ...1 46 2004 Buell P3 Maintenance HOME NOTES ...
Страница 79: ......
Страница 154: ......
Страница 155: ......
Страница 205: ...3 50 2004 Buell P3 Engine HOME NOTES ...
Страница 239: ......
Страница 267: ...4 28 2004 Buell P3 Fuel System HOME NOTES ...
Страница 269: ......
Страница 270: ......
Страница 292: ......
Страница 308: ...6 16 2004 Buell P3 Drive Transmission HOME NOTES ...
Страница 334: ......
Страница 408: ......