1

 

Safety considerations

Logano G

C

 124 II – 6 720 804 440 (2012/11)

3

1

Safety considerations

1.1

Key to symbols

Warnings

The following keywords are defined and can be used in this document:

NOTE

 indicates a situation that could result in damage to property or 

equipment.

CAUTION

 indicates a situation that could result in minor to medium 

personal injury.

WARNING

 indicates a situation that could result in severe personal 

injury or death.

DANGER

 indicates a situation that will result in severe injury or death.

Important information

Additional symbols

1.2

Safety instructions

Observe these instructions for your safety.

The burner and control must be correctly installed and adjusted to 
ensure safe and economical operation of the gas boiler.

Read this installation and maintenance manual carefully and note the 
details on the boiler nameplate before placing the boiler in operation.

Risk of fatal injury from explosion of flammable gases

If you smell gas there is a danger of explosion.
▶ Never work on gas lines unless you are licensed for this type of work.
▶ Make sure that a qualified company installs the boiler, connects gas 

and ventplaces the boiler in operation, connects the electrical power, 
and maintains and repairs the boiler. 

▶ No open flame! No smoking! Do not use lighters
▶ Prevent spark formation.  Do not operate electrical switches, 

including telephones, plugs or door bells.

C

lose main gas valve.

▶ Open doors and windows.
▶ Warn other occupants of the building, but do not use door bells.

C

all gas company from outside the building.

▶ If gas can be heard escaping, leave the building immediately, prevent 

other people from entering, notify police and fire departments from 
outside the building.

Risk to life from electrical shock.

▶ Disconnect the power supply to the boiler heating system before 

conducting any work on it, e.g. turn off the heating system emergency 
switch outside the boiler room.

▶ It is not sufficient just to turn off the control.
▶ Do not carry out electrical work unless you are qualified for this type 

of work.

▶ Before disconnect electrical power completely and pad lock to 

prevent accidental reconnection.

▶ Observe the local installation regulations.

Risk of fatal injury from flue gas poisoning

Insufficient ventilation or combustion air availability may cause 
dangerous flue gas leaks or formation.
▶ Make sure that inlets and outlets are not reduced in size or closed.
▶ If faults are not corrected immediately, the boiler must not be 

operated until all faults have been corrected.

▶ Inform the system operator and/or owner of the fault and the danger 

in writing.Elektroanschluss nur durch eine Elektrofachkraft ausführen 
lassen.

When working on the flue gas venting equipment or vent damper leakage 
of flue gases may endanger the lives of people.

C

arefully observe proper operation of the vent damper. Do not start 

up the boiler unless the vent damper is operating properly.

▶ Use only original parts when replacing parts.
▶ When replacing the vent damper, install the new one in the specified 

position.

Risk to life by poisoning by spillage of flue gases

▶ If the blocked vent switch trips frequently the fault must be corrected 

and proper operation of the blocked vent switch test must be 
conducted.

Risk to life by poisoning by leakage of flue gases

▶ Make sure that the boiler is not equipped with a thermally controlled 

flue gas vent damper after the open draft hood.

Risk of fatal injury from neglecting your own safety in case of 
emergency, such as with a fire

▶ Never put yourself at risk. Your own safety must always take priority.

Fire danger due to flammable materials or liquids

▶ Make sure that there are no flammable materials or liquids in the 

immediate vicinity of the boiler.

▶ Maintain a minimum distance of 15 inches from the boiler.

Installation and maintenance

▶ Observe all current standards and guidelines applicable to the 

installation and operation of the boiler heating system as applicable in 
your state or local jurisdiction.

C

lean and service the boiler system once a year. 

C

heck that the 

complete heating system operates correctly.

▶ Immediately correct all faults to prevent system damage.
▶ Only use original Buderus spare parts. Losses caused by the use of 

parts not supplied by Buderus are excluded from the Buderus 
warranty.

Warnings in this document are identified by a warning 
triangle printed against a grey background.
Keywords at the start of a warning indicate the type and 
seriousness of the ensuing risk if measures to prevent 
the risk are not taken.

This symbol indicates important information where 
there is no risk of personal injury or property damage.

Symbol

Explanation

Step in an action sequence

 

C

ross-reference to another part of the document

List entry

List entry (second level)

Table 1

Содержание Logano GC 124 II

Страница 1: ...efore placing this boiler in operation observe the safety instructions of this installation and mainte nance manual CAUTION The operating manual is a component of the tech nical documentation handed o...

Страница 2: ...s for combustion air supply and venting 12 9 Requirements for connection to chimneys or venting systems 13 10 Flue pipe installation 13 11 Placing the heating system in operation 14 11 1 Starting up t...

Страница 3: ...bility may cause dangerous flue gas leaks or formation Make sure that inlets and outlets are not reduced in size or closed If faults are not corrected immediately the boiler must not be operated until...

Страница 4: ...e ANSI Z 223 1 If specified by the local regulatory authorities the heating system must comply with the regulations of the Standard for Controls and Safety Devices for Automatically Fired Boilers ANSI...

Страница 5: ...oiler 2 3 8 RK 1 VK 1 GAS EL GAS 6 720 804 440 02 1T Boiler size Boilerinput A B Vent connection II Min relief valve capacity Number of Orifices Water volume Dry weight Btu hr Inches Inches Inches lb...

Страница 6: ...ponent Qty Packaging method Boiler complete 1 1 palette B kit components 1 1 4 supply manifold 30 psi relief valve long shank boiler drain pressure temperature gauge 90 elbow 1 x 1 NPT 90 elbow 1 x 1...

Страница 7: ...and horizontal The boiler may be installed on a flammable base but not on carpet Fig 7 Required clearances in the boiler room 1 Recommended service clearances 2 Required minimum clearances 3 Burner tr...

Страница 8: ...ut off Thelow watercut offmustbeinstalledduring installation of the boiler and placed above the water level in the boiler without any means of shutting the water off between the boiler and low water c...

Страница 9: ...ust be grounded as specified by the regulations of the relevant local authorities otherwise follow the regulations of the National Electrical Code ANSI NFPA 70 The boiler is fully functional with the...

Страница 10: ...jacket if required by the local code We recommend installing a manual shut off valve in the main gas pipe to the boiler The gas pipe must be fastened outside the boiler The local codes must be observ...

Страница 11: ...iler slowly with water from the feed water connection Open automatic vents slightly to allow the air to escape Slowly fill heating system Observe pressure display on pressure gauge during this process...

Страница 12: ...iler room calculated from the outer edge of the opening The shortest dimension of all inlet and outlet openings must not be less than three inches Total air supply from outside the building Make sure...

Страница 13: ...nspect the venting system to ensure that it has the correct dimensions and longitudinal inclination Make sure that the system is not blocked leaking corroded or has any other faults that cause it to o...

Страница 14: ...ed in the boiler have been tested at the factory as described in ANSI Z 21 13 to ensure safe operation of the heating system and verify specific performance indicators Preparing for operation Set the...

Страница 15: ...n the gasvalve Installpressure measuring nipple andattach a pressure gauge to measure the orifice pressure Open gas shut off Fig 20 Gas valve 1 ON OFF knob shown in ON position 2 Screw plug for gas pr...

Страница 16: ...e 1 ON OFF knob shown in ON position Checking gas supply pressure Check the gas supply pressure while the boiler is operating The connection pressure for natural gas must be between 4 7 and 10 5 W C F...

Страница 17: ...shut off The main burner flame figure 25 and the ignition flame are extinguished After no more thansix 6 secondsthemaingassolenoidvalveonthegasvalvemust close with an audible noise If the gas valve do...

Страница 18: ...to the OFF position Disconnect the heating system from the power source and turn thermostat to its lowest setting Seal leaks Repeat all steps in this paragraph Carefully wipe away the soapy water to p...

Страница 19: ...ion Start up procedure Remarks or measured values 1 Type of gas Natural gas LP 2 Has the leak test been completed 3 Check combustion air inlet and outlet openings and flue gas connection 4 Check the e...

Страница 20: ...stion air air inlets and Ventilation openings Check the venting system including the combustion air inlet and outlet openings All faults must be repaired immediately Make sure that the combustion air...

Страница 21: ...figure 39 page 23 If the igniter flame is acceptable start cleaning Fig 33 Gas valve 1 Safety screw on igniter adjustment screw 15 5 1 Cleaning the boiler with brushes Burner removal Beforeopeningaun...

Страница 22: ...ace cleaning cover install screws and replace insulation 15 5 2 Wet cleaning chemical cleaning For wet cleaning use a suitable cleaning agent depending on the degree of build up of dirt soot or scale...

Страница 23: ...s line screw Rinse out burner rods with a water jet hold burner so water enters all slots of the burner rods and drains back out Fig 40 Moving burner back and forth to remove water Remove remaining wa...

Страница 24: ...rmthatall maintenace work has been conducted Sign the maintenance protocol and discuss it with the owner of the heating system Be careful not to damage the pilot orifice during installation and cleani...

Страница 25: ...er page 20 4 Cleaning of boiler page 21 5 Cleaning of burner page 23 6 Measuring gas supply pressure page 16 inches W C inches W C 7 Measuring orifice pressure page 16 inches W C inches W C 8 Checking...

Страница 26: ...nd maintenance Logano GC 124 II 6 720 804 440 2012 11 26 Date Date Date Date Date inches W C inches W C inches W C inches W C inches W C inches W C inches W C inches W C inches W C inches W C Table 13...

Страница 27: ...f everything is OK replace automatic ignition No Heat requirement ended system switches off flue baffle closes End of troubleshooting Repeat procedure until heating system operates properly On models...

Страница 28: ...ition flame Specified thermostat value control reached Main and ignition gas valves close gas burners ex tinguished flue gas baffle if installed closes Ignition burner operation Ignition flame burns a...

Страница 29: ...ly valid in the U S A and only for elevations from 0 8500 ft Boiler size Number of orifices Main gas orifice identification for elevations from feet in ft3 h inch W C 0 8500 ft 1 1 installation attitu...

Страница 30: ...yellow black 4 R W L2 Plug Plug PV Intermittent pilot control module S8600H Connecting terminals for thermostat 2 Burner assembly Terminals on boiler block Main supply power use circuit breaker as req...

Страница 31: ...Pilot Burner Spark Gas valve Main Pilot PV PV MV GND MV S8600H GND PV PV MV MV 24V 24VGND K1 TR High Limit Flame roll out safety shutoff switch K2 B2 L2 N L 24V AWG 18 WIRE 120 VAC Wiring Schematic G...

Страница 32: ......

Отзывы: