Tank Assembly
Logalux SM300/1 - SM400/1 - Technical specifications are subject to change without prior notice.
16
4.2.2
Installation of Tank Insulation for SM400/1
Tank
V
Route sensor wiring carefully along tank shell.
V
Connect both pieces of insulation [6] on the front of the
tank shell.
V
Slide front cover pieces [4] in place.
V
Connect both insulation pieces at the back side of the
tank.
V
Slide small locking pieces [5] in place.
V
Fully engage the front cover pieces.
V
Further tighten the insulation in the back of the tank.
V
Put top foam piece [2] and top cover [1] in place.
Review entire insulation for proper fit.
Fig. 14 Insulation installation for SM400/1 tank
1
Tank top cover
2
Top insulation piece
3
Cover of top of locking piece
4
Front locking piece
5
Short locking piece
6
Insulation
7
Bottom insulation disc
We recommend to only installing the insula-
tion after all piping and a water test has been
successfully completed.
The insulation is best installed at a room tem-
perature of 59 °F/15 °C. Slight tapping on
the insulation in the direction of the connec-
tion eases the installation of the insulation.