6.4
Placing solar tank back in operation
after cleaning
V
Install new gasket with clean-out cover.
V
Tighten 6 bolts by hand.
V
Further tighten the bolts with a wrench. Tighten evenly.
Torque bolts evenly to about 25 - 30 Nm (18 - 22 lb-ft).
V
Fill the solar water heater and start up the system.
V
Check all connections and clean-out cover for leaks.
V
Install insulation piece and clean-out cover.
V
Put insulation piece and top cover back on the top of
the tank. (
Æ
Fig. 1, page 5).
Fig. 23 Installation of inspection cover.
1
Inspection opening
2
Clean-out cover gasket
3
Magnesium anode rod
4
Clean-out cover
5
Hex head bolts
6
Insulation piece
7
Clean-out cover and screws
Caution:
Tank damage due to a defective
gasket!
V
To avoid leak sites, replace the clean-out
gasket following removal of the clean-out
cover.