Appendix
7
Installation and maintenance instructions for wall-mounted condensing gas boiler 600 - 11S/19S/24S/24C • 02/2006
63
Subject to modifications resulting from technical improvements!
Buderus • http://www.buderus-domestic.co.uk
Dimensions
Unit
600 Series wall-mounted condensing gas boiler
11S
19S
24S
24C
Pipe connections
Gas
inch / mm
G1"
Ø22 mm
compression
fitting
Heating water
mm
Ø22 mm compression fitting
Domestic water
mm
Ø15 mm compression fitting
Condensate-water outlet
inch
G1"
Flue gas values
Condensate water quantity, natural gas,
40/30
°
C
l/h
0.7
1.3
1.6
1.6
pH value of condensate water
approx. 4.1
Exhaust-fume mass-flow rate
Full load
Part-load
g/s
g/s
4.9
2.2
8.4
4.3
10.6
4.3
10.6
4.3
Exhaust-fume temperature, full load
Heating curve 75/60
°
C
Heating curve 40/30 °C
°C
°C
75
50
85
55
95
55
95
55
Exhaust-fume temperature, part-load
Heating curve 75/60
°
C
Heating curve 40/30 °C
°C
°C
65
40
70
45
70
45
70
45
CO
2
full load, natural gas
standard test gas G20
%
9.2
CO
2
full load, natural gas
standard test gas LPG
%
10.3
Standard emission factor CO
mg/kWh
<22
Standard emission factor NO
x
mg/kWh
<30
Flow pressure available for use
Pa
35
60
100
100
Flue-gas system
Type of exhaust-fume connection
C
13
, C
33
, C
53
Diameter of flue gas system
mm
60/100
Electrical data
Mains connection voltage
V
230
Electrical power consumption
Full/Part load
W
105/100
110/105
115/105
115/105
Electrical protection rating
IPX4D
Boiler dimensions and weight
Height x Width x Depth
mm
850 x 480 x 370
Weight (without casing)
kg
39
40
40
45
Casing
kg
7
7
7
7