Code
Meaning
5C
Boiler shut down after connection with Service Tool
Possible
cause
Action
1
Service tool connection
Press reset. If fault code remains than try to temporarily
connect a different UBA (see subsection 5.3.3)
2
A short or bad connection in the cable harness
Check the cable harness and/or connector of the sensor
3
UBA might be faulty
Check the UBA by temporarily connecting an other UBA
(see subsection 5.3.3)
Code
Meaning
6A
F1 fuse defective, or no ionisation message after ignition
Possible
cause
Action
1
There is no flame, ionisation electrode doesn’t
glow, fan is turning
– Check wiring of the hot surface ignitor, measure the resistance
of the hot surface ignitor (should be between 50 and 300 Ohm).
Replace hot surface ignitor if necessary (see subsection 5.3.19
and subsection 5.3.20)
– Check the UBA’s F1 fuse, replace if necessary
2
There is no flame, ionisation electrode does
glow, fan isn’t turning
– Check the fan and KIM connectors and the UBA fuses
3
There is no flame, ionisation electrode and fan
are working
– Check and adjust the gas/air ratio (see subsection 2.1.12)
– Check for 24 V~ on the gas valve during start up
– Check the gas-supply pressure (see subsection 2.1.11), this
should be higher than 20 mbar for natural gas.
– Check the earthing cable connections
(yellow/green wire).
– Check the cabling on the ionisation electrode
4
There is a flame, but the flame disappears
when the fan starts up
– Check the gas-supply pressure (see subsection 2.1.11), this
should be higher than 20 mbar for natural gas.
– Check and adjust the gas/air ratio (see subsection 2.1.12)
– Check the earthing cable connections (yellow/green wire)
– Check the cabling on the ionisation electrode
– Press reset. If fault code remains than try to temporarily connect