OPERATIONS
POWERmini USB User Guide 2.1.0A
6
350-00103-5
Power System Monitoring
The Status and Systems Report pages provide information about input and output power and the state of
the battery.
Status Page
The left side of the Status page provides digital information about the battery including battery voltage,
load current and the amount of charge that has been provided by the battery to the load since power has
been applied.
The status of the audible alarm is also indicated here. When the alarm is enabled an asterisk is displayed
at the lower left of the page. The asterisk is not shown when the audible alarm is disabled.
Two vertical bar graphs are displayed at the center of the status screen. These provide a view of the
battery state of charge and the instantaneous load current (see Figure 8).
The upper and lower voltage thresholds are also shown as the thicker bars at the top and bottom of the
voltage bar.
Battery voltage
Load current
Figure 8 Left side of Status
page
Low voltage limit
High voltage limit
The lower edge of the box indicates the high
voltage disconnect (HVD) threshold.
Battery capacity
used
Audible Alarm
Enable Indicator
Warning messages
Battery voltage marker
The vertical position of the marker is from 10V
to 16V (illustration shows 13.61V).
Load current
The height of the bar graph indicates the
instantaneous current flowing to the load (full
scale =35A).
The right side of the Status page provides information about the solar panel performance.
See Figure 9 below for a brief description of the various fields.
Figure 9 Right Side of
Status page
Solar panel output voltage
The solar panel voltage will be different from the battery voltage when the
panel is not charging the battery.
Solar panel output current
The current being delivered from the solar panel to the battery.
Solar panel contribution to battery
The total charge delivered by the panel to the battery.
Solar Charge indicator
Indicates if the charger is in charge, float mode or off.