Control Settings 

This page contains settings for auto-cutoff audible alarm, over-voltage and under-voltage limits. 

When Auto-Off is enabled POWERmini will automatically disconnect the load from the battery.  When 
Auto-off is disabled the output will not be disconnected but an audible alarm (if enabled) will sound.  

Over voltage settings control the point at which POWERmini USB will disconnect or reconnect the battery 
and the load.  

 

 

 

Figure 7 Control Settings page 

 

Auto off 

(Enable/Disable) 

Select whether auto-shutdown is enabled or not. 

Alarm 

(Enable/Disable) 

Enable or disable the audible alarm that indicates when 
an over voltage or under voltage condition has 
occurred. 

HV trip 

(15- 16V) 

The output is automatically disconnected when it 
exceeds this trip voltage 

HV reset 

(0.5 

 1.5 below the HV trip setting) 

The output is reconnected after a HV trip when the 
voltage is at or below this voltage limit 

 
 

 

Содержание PowerMini USB

Страница 1: ...ted device incorporates the functions of a solar charge controller battery management system power monitoring device and power distribution in a small robust and weather resistant package Despite its...

Страница 2: ...WER SYSTEM MONITORING 6 Status Page 6 System Report 7 OTHER FUNCTIONS 8 Display Timeout 8 Auto Shutdown under voltage condition 8 Auto Shutdown over voltage condition 8 Output Overload 8 Audible Alarm...

Страница 3: ...e USB charger output The DC power outputs are on the right side of the unit All power connections use the popular Anderson Powerpole family of low voltage high current connectors which are popular in...

Страница 4: ...should be connected to the negative connection of the radio Before connecting to the radio confirm the connections are correct using a DC voltmeter DMM Press the SEL button briefly twice to view the B...

Страница 5: ...e with different types of battery User settings include Low battery voltage trip point reset point and early warning of low battery Automatic disconnect provides protection from deep discharge Max cha...

Страница 6: ...s to change the value Figure 5 Edit Threshold Voltage Edit page Edit box Each press of the SEL button moves the box to the next entry Moving to the next line To skip to another line briefly press the...

Страница 7: ...oltage settings control the point at which POWERmini USB will disconnect or reconnect the battery and the load Figure 7 Control Settings page Auto off Enable Disable Select whether auto shutdown is en...

Страница 8: ...p and bottom of the voltage bar Battery voltage Load current Figure 8 Left side of Status page Low voltage limit High voltage limit The lower edge of the box indicates the high voltage disconnect HVD...

Страница 9: ...ls Figure 10 System Report page Power Up Time The operating time since the unit was powered on Solar Power The instantaneous solar panel power output Solar Peak The maximum output of the solar panel s...

Страница 10: ...hether the auto shutdown mode is enabled or not if the battery voltage falls below 10 1V POWERmini USB will automatically shut down and will not restart until it is reset by disconnecting and then rec...

Страница 11: ...Rmini solar input will be automatically disconnected and the warning message FAULT will be displayed in the bottom of the solar panel window To reset the POWERmini solar input disconnect the solar pan...

Страница 12: ...ltage reset 15 V Restore Factory Defaults Use the following procedure to reset the unit back to the default factory settings Disconnect the POWERmini USB from the battery and solar input Press and hol...

Страница 13: ...higher maximum voltage 100 charge level and a relatively flat discharge curve These batteries can also provide very high output currents relative to their Ah rating Lead Acid battery The battery a lo...

Страница 14: ...not charge a 12V battery if the total battery voltage is below 10V If you have a battery that has an abnormally low terminal voltage then you may be able to recover it by using a very low charge curr...

Страница 15: ...isconnect range 14 16 V user adjustable Low voltage disconnect range 9 5 13 V user adjustable Maximum Charge Voltage 10 15 V user adjustable Audible alarm User settable enable disable Overall Size 4 5...

Отзывы: