OPERATIONS
POWERmini USB User Guide 2.1.0A
10
350-00103-5
Default Settings
The following table shows the values that are set at the factory, but these can be changed to better suit
your needs if required.
PARAMETER
DEFAULT VALUE
Battery Type
Lithium Iron Phosphate (LiFePO4 -14V)
Max Charge Voltage
14.4 V
Auto Off
Disabled
Audible alarm
Enabled
Low voltage limit
11.0 V
Low voltage reset
11.5 V
High voltage limit
15.5 V
High voltage reset
15 V
Restore Factory Defaults
Use the following procedure to reset the unit back to the default factory settings.
•
Disconnect the POWERmini USB from the battery and solar input
•
Press and hold the SEL button and connect the battery to the battery input port
•
When the start-up screen has displayed, and you hear a brief beep, release the SEL button
•
Reconnect the solar panel (if in use)
The default values will have been restored to the system. Before using the device please check that you
have settings that are suited to your system. It is particularly important to check that the correct battery
type has been selected.