background image

5 | Installation

Büchi Labortechnik AG

22/78

Operation Manual Rotavapor® R-250 Pro

u

Secure the support rod in place with a headless
screw.

5.4

Installing the glassware

NOTE

Glassware is delivered as per the purchase order, order confirmation and delivery
note.

5.4.1

Glassware assembling instructions

Assembling instruction EasyClamp DN40

u

Attach the two glass pieces.

4

3

2

1

3

u

Secure the connection in place with the easy
clamp.

Assembling instruction EasyClamp DN25

u

Attach the two glass pieces.

4

2

1

3

Содержание Rotavapor R-250 Pro

Страница 1: ...Rotavapor R 250 Pro Operation Manual 11594225 A en...

Страница 2: ...s the right to make changes to the manual as deemed necessary in the light of experience especially with respect to structure illustrations and technical details This manual is copyrighted Information...

Страница 3: ...High internal pressure 10 2 7 3 Hot surfaces and liquids 10 2 7 4 Rotating parts 10 2 7 5 Faults during operation 10 2 7 6 Glass breakage 10 2 8 Modifications 11 3 Product description 12 3 1 Descripti...

Страница 4: ...pply with a recirculating chiller option 33 5 6 2 Installing the cooling water supply without a recirculating chiller option 34 5 7 Heating bath installations 35 5 7 1 Installing the splash protection...

Страница 5: ...g the overtemperature protection 56 10 4 Replacing the inlet valve plunger 56 10 5 Adjusting the cooling water flow sensor 57 10 6 Adjusting the level sensor 57 10 7 Adjusting the foam sensor 57 11 Ta...

Страница 6: ...character draws attention to a requirement that must be met before the instructions below are carried out u This character indicates an instruction that must be carried out by the user This character...

Страница 7: ...in areas which require explosion safe instruments Use of the instrument for processing substances in the food animal feed or cosmetics industries Use of samples which can explode or inflame example ex...

Страница 8: ...service technicians Service technicians authorized by BUCHI have attended special training courses and are authorized by B CHI Labortechnik AG to carry out special servicing and repair measures 2 4 P...

Страница 9: ...vice damage Dangerous electrical voltage Hot surface Hand injuries Fig 1 Location of the warning symbols on the instrument 2 7 Residual risks The device has been developed and manufactured using the l...

Страница 10: ...acuum connection open 2 7 3 Hot surfaces and liquids The heating bath evaporating flask and parts of the condenser can become very hot If touched they can cause skin burns u Do not touch hot surfaces...

Страница 11: ...s for damage every time they are to be used u Do not continue to use glass components that are damaged u Always wear protective gloves when disposing of broken glass 2 8 Modifications Unauthorized mod...

Страница 12: ...o the coolant fluid so that the vapor re condenses The resulting solvent is collected in the receiving flask and can then be reused or properly disposed of Distillation under vacuum Distillation capac...

Страница 13: ...1 U tube 2 Distribution piece 3 Gear box 4 Snap flange coupling 5 Evaporation flask 6 Heating bath 7 Castor wheels 8 Holder vacuum pump option 9 Drain valve heating bath 10 Heating bath lift 11 Hex k...

Страница 14: ...le glassware 1 Expansion vessel 2 Vapor temperature sensor 3 Condenser 4 Support rod 5 Yoke 6 Receiver aeration valve 7 Cooling water flow sensor option 8 Vacuum valve option 9 Aeration valve 10 Heati...

Страница 15: ...on slots 2 VacuBox see Operation Manual Interface I 300Pro 3 Cooling water temperature marked CW TEMP 4 Level sensor 2 marked LEVEL 2 5 Reserve marked R SERVE INPUT 6 BUCHI standard communication port...

Страница 16: ...s of the configuration of the purchase order Accessories are delivered as per the purchase order order confirmation and delivery note 3 4 Type plate The type plate identifies the instrument The type p...

Страница 17: ...on degree 2 Overvoltage category II Pump outlet max 2 A Rotation speed range 5 120 rpm Heating bath temperature range 20 180 C 2 C Adjustment accuracy 1 C Regulation precision At 60 C 1 C At 95 C 2 C...

Страница 18: ...allation site meets the requirements for the connected devices See related documentation The installation site meets the safety requirements See Chapter 2 Safety page 7 The installation site meets the...

Страница 19: ...ransport NOTICE Risk of breakage due to incorrect transportation u Make sure that the device is fully dismantled and all parts of the device are safely packed in such a way as to prevent breakage idea...

Страница 20: ...4 Transport and storage B chi Labortechnik AG 20 78 Operation Manual Rotavapor R 250 Pro u Loosen the transportation lock screws u Remove the transportation lock...

Страница 21: ...ctrician or a person with similar expert knowledge u After installation check electrical safety The instrument is design for stationary installation Precondition R The electrical installation is as sp...

Страница 22: ...the glassware NOTE Glassware is delivered as per the purchase order order confirmation and delivery note 5 4 1 Glassware assembling instructions Assembling instruction EasyClamp DN40 u Attach the two...

Страница 23: ...u Secure the connection in place with the easy clamp Assembling instruction glass bracket u Attach the glass bracket to the condenser Assembling instruction bracket u Attach the expansion vessel to th...

Страница 24: ...ruction shut off tap NOTICE Tighten the shut off tap with your hands u Attach the shut off tap to the glassware using the white handle 5 4 2 Installing the inlet valve example u Attach the inlet valve...

Страница 25: ...truction bracket page 23 3 See Chapter Assembling instruction glass bracket page 23 4 See Chapter Assembling instruction bracket page 23 5 See Chapter Assembling instruction EasyClamp DN40 page 22 6 S...

Страница 26: ...2 3 See Chapter Assembling instruction glass bracket page 23 4 See Chapter Assembling instruction glass bracket page 23 5 See Chapter Assembling instruction bracket page 23 6 See Chapter Assembling in...

Страница 27: ...ceiving vessel support page 24 3 See Chapter Assembling instruction EasyClamp DN25 page 22 4 See Chapter Assembling instruction EasyClamp DN25 page 22 5 See Chapter Assembling instruction shut off tap...

Страница 28: ...hapter Assembling instruction EasyClamp DN25 page 22 3 See Chapter Assembling instruction shut off tap page 24 4 See Chapter Assembling instruction EasyClamp DN25 page 22 5 4 8 Connecting the receiver...

Страница 29: ...epared See related documentation u If possible locate the vacuum pump at the vacuum pump location of the instrument See Chapter 3 2 Configuration page 13 u Attach the vacuum hose to the Aeration valve...

Страница 30: ...f a vacuum pump is used prepare the vacuum pump See related documentation u Attach the vacuum valve to the instrument u Attach the vacuum hose to the vacuum valve u Connect the vacuum valve and the ae...

Страница 31: ...31 78 u Attach the vacuum hose to Y piece u Attach the condenser vacuum hoses to the Y piece u Attach the vacuum hoses to the condensers u Attach the hose barb to the condenser u Attach the vacuum hos...

Страница 32: ...Box 5 5 5 Installing the vacuum connection glass assembly D option u Attach the vacuum hoes to the Aeration valve u Attach the vacuum hose to the condenser u Attach the hose barb to the condenser u At...

Страница 33: ...umentation R The inlet water hose for the condenser is prepared u Connect the chiller cable to the related connection on the instrument See Chapter 3 2 Configuration page 13 u Attach the inlet water s...

Страница 34: ...lating chiller option Precondition R The water supply meets the technical specification See Chapter 3 5 Technical data page 17 u Attach the water supply hose to the cooling water tap u Secure the wate...

Страница 35: ...outlet water supply hose to the Y piece u Attach the outlet condenser hoses to the Y piece u Secure the hoses in place with a hose clamp u Put the other end of the hose in a sink 5 7 Heating bath inst...

Страница 36: ...ting bath NOTE u If a heating medium other than clean water is used Obey local regulations and statutory requirements regarding disposal u Attach the drain hose to the drain valve u Install the other...

Страница 37: ...s assembly D option page 37 Installing the vapor temperature sensor at the glass assembly R option u Attach the vapor temperature sensor to the distribution piece u Connect the vapor temperature senso...

Страница 38: ...distribution piece has the option to install a foam sensor u Attach the foam sensor to the to the distribution piece u Connect the sensor cable to the related connection on the instrument See Chapter...

Страница 39: ...onnect the sensor cable to the related connection on the instrument See Chapter 3 2 Configuration page 13 u Activate the sensor in the sensor menu See Chapter 5 8 6 Setting up the sensors page 39 u If...

Страница 40: ...Tap the up button to change the status for the level sensor 1 according the requirements u Tap the Aerate button on the interface The setting for the level sensor 1 is saved The instrument shows the...

Страница 41: ...1 78 u Install the cover in place u Connect the connection cable to the BUCHI standard communication port COM on the interface u Connect the other end of the connection cable to the BUCHI standard com...

Страница 42: ...e 4 According to the current operation Rotation speed Error code 5 UP button According to the current operation Bath lift Sensor settings 6 Down button According to the current operation Bath lift Hea...

Страница 43: ...moving the evaporation flask NOTE Removing is done in reverse sequence u Move the heating bath in a lower position u Put the evaporation flask and the flask handler option an the instrument u Lift the...

Страница 44: ...g the inlet valve u Attach the solvent hose to the inlet valve u Put the solvent hose into the solvent u Set the flow rate 7 3 Preparing the heating bath CAUTION Risk of skin burns from oil splashes u...

Страница 45: ...13 7 4 Draining distillate Precondition R A distillate collection is available u Close the shut off tap u Make sure that the plunger closes the hole u Loose the aeration valve u Open the drain valve...

Страница 46: ...7 Preparing for an evaporation B chi Labortechnik AG 46 78 Operation Manual Rotavapor R 250 Pro u Secure the splash protection in place...

Страница 47: ...or open the water tap u Set the vacuum option on the Interface See operation manual Interface I 300 Pro u Add product Add product See Chapter 7 2 Operating the inlet valve page 44 u Lift the heating b...

Страница 48: ...8 Carrying out an evaporation B chi Labortechnik AG 48 78 Operation Manual Rotavapor R 250 Pro 8 5 Shutting down the instrument u Switch the On Off master switch to off...

Страница 49: ...ethanol u Wipe the sealing lip with a soft lint free cloth monthly Instrument u Perform a leak test See operation manual Interface I 300 Pro u If necessary search for leaks u If necessary change the...

Страница 50: ...flask seal NOTE Installing is done in reverse sequence u Remove the snap flange coupling with the provided tool NOTICE Make sure that the vapor duct does not fall down during carrying out this action...

Страница 51: ...light force and turn the vapor duct until the shaft starts turning 9 5 Setting max heating bath temperature u Push and hold the SET button u Set the On off master switch to On SET u Select the maximum...

Страница 52: ...ure sensor is de fect u Contact BUCHI Customer Service Over temperature protec tion is active u Reset over temperature protection See Chapter 10 3 Resetting the overtemperature protection page 56 Evap...

Страница 53: ...e instrument u Rotate evaporating flask manually u Check for causes of the blocking and remove u Contact BUCHI Customer Service The rotary drive is blocked E04 The battery voltage is too low u Switch...

Страница 54: ...I Customer Service E13 The receiving vessel 1 filling level is reached u Empty receiving vessel 1 u Press the Aerate button u Adjust the level sensor See Chapter 10 6 Adjusting the level sensor page 5...

Страница 55: ...rotection See Chapter 10 3 Resetting the overtemperature protection page 56 u Contact BUCHI Customer Service E32 Heating bath runs dry Temperature 200 C u Switch off the instrument u Wait until the he...

Страница 56: ...x ternal electrical consumers 24 V u Unplug the external consumer u Replace external defective consumer u Contact BUCHI Customer Service E43 Electronic malfunction u Start the instrument again u Conta...

Страница 57: ...ws an error u Secure the sensor in place with the screw u Switch the water supply to on The error on the display disappear 10 6 Adjusting the level sensor Status LED Explanation ON Liquid is detected...

Страница 58: ...ro Precondition R The sensor is connected to the instrument See Chapter 5 8 3 Installing the foam sensor option page 38 u Remove the protective cover u Put the sensor 1 cm in the product u Adjust the...

Страница 59: ...bles from the device 11 2 Disposal The operator is responsible for proper disposal of the instrument u When disposing of equipment observe the local regulations and statutory requirements regarding wa...

Страница 60: ...nser Vapor temperature sensor Other vacuum source option Autodest Sensor option Foam sensor option VacuBox Vacuum Valve Fig 11 Vacuum connection 12 1 2 Cooling water circuit Cooling water flow sensor...

Страница 61: ...577 003577 003577 003577 003577 003577 003577 003577 027289 027289 027289 027289 027289 027289 041130 041130 041130 041131 041131 041155 041155 041159 041159 005155 005155 041336 041348 027277 041338...

Страница 62: ...041131 Pivoting clamp complete 041151 Glass clamp 100 mm complete 041155 Cooler 3 coil closed PLG 041159 Set of bolts for EasyClamp DN25 041240 Set of bolts for EasyClamp DN40 041241 Distillate coole...

Страница 63: ...27277 Spare parts glass assembly RB 003577 003577 003577 003577 003577 003577 003577 003577 005155 005155 027289 027289 027289 027289 027289 027289 027824 027824 041130 041130 041130 041131 041131 041...

Страница 64: ...041131 Pivoting clamp complete 041151 Glass clamp 100 mm complete 041155 Cooler 3 coil closed PLG 041159 Set of bolts for EasyClamp DN25 041240 Set of bolts for EasyClamp DN40 041241 Distillate coole...

Страница 65: ...acuum feeding industrial Rotavapor 027277 Spare parts glass assembly D 001165 041335 041348 027277 041334 041337 001129 005155 041130 041076 003577 003577 003577 003577 027289 027289 027289 027289 027...

Страница 66: ...rature sensor complete 041076 EasyClamp DN25 041130 EasyClamp DN40 041131 Pivoting clamp complete 041151 Glass clamp 100 mm complete 041155 Cooler 3 coil closed PLG 041159 Set of bolts for EasyClamp D...

Страница 67: ...e per m Use Vacuum feeding industrial Rotavapor 027277 Spare parts glass assembly D3 001165 005155 027277 041076 041159 041334 041335 041337 041436 041130 003577 003577 003577 003577 003577 003577 027...

Страница 68: ...oil PLG 027308 Vapor temperature sensor complete 041076 EasyClamp DN25 041130 EasyClamp DN40 041131 Pivoting clamp complete 041151 Glass clamp 100 mm complete 041155 Cooler 3 coil closed PLG 041159 Se...

Страница 69: ...Order no Image Inlet valve complete 041348 Extension 041270 Order no PTFE hose connection SVL 22 027338 Seal PTFE 005155 Tubing PTFE 8 10 mm white per m Use Vacuum feeding industrial Rotavapor 027277...

Страница 70: ...0 78 Operation Manual Rotavapor R 250 Pro Order no Image EasyClamp DN25 041130 Industrial tap small 041062 Angle seat drain valve 041405 Receiving flask 20 lt PLG 041446 Branching piece R 250 PLG 0414...

Страница 71: ...s double receiver 041445 041048 041048 041130 041130 041130 041130 041130 041130 041062 041062 041405 041405 041446 041446 041480 041480 Order no Image Branching piece 1 PLG 041048 EasyClamp DN25 0411...

Страница 72: ...rder no Image O ring 130x5 0 Fpm70 027378 EasyClamp element DN70 041135 PTFE coated silicon gasket for DN25 set of 5 11056381 PTFE coated silicone gasket for DN40 set of 5 11065382 Set of 5 O rings 64...

Страница 73: ...ix 12 Operation Manual Rotavapor R 250 Pro 73 78 Order no Image Reducer x 041448 12 2 3 Inlet valve Order no Image PTFE bellow 041388 Glass body 041346 Set of 5 SVL 15 seals 041946 Screw Cap SVL 15 00...

Страница 74: ...condenser Capacity and final vacuum 3 1 m h 1 5 mbar 11V600810 Holder vacuum pump 11071091 Manual flask handler for 50 L flask For easy mounting and removal of the flasks along with safe transport 04...

Страница 75: ...he coolant temperature for optimal dis tillation settings 11055988 Cooling water valve Eliminates unnecessary water waste by stopping cooling water flow when not in use 041191 Level sensor for receivi...

Страница 76: ...k handler 041494 12 2 5 Hoses Order no Image Softaflex ID 19 mm 037617 Y piece 12 mm 16 mm 041473 Order no Tubing PVC 10 15 mm transparent per m Use cooling tube to Rotavapor R 220 Pro 027146 PVC hose...

Страница 77: ...12 Operation Manual Rotavapor R 250 Pro 77 78 12 2 6 Gear box Order no Image Seal tool 020075 Vapor duct 041084 Seal holder 041094 Vacuum seal 041095 Evaporating flask seal complete 041121 Set of 5 di...

Страница 78: ...91 22 667 18986 india buchi com www buchi com in en Indonesia PT BUCHI Indonesia ID Tangerang 15321 T 62 21 537 62 16 F 62 21 537 62 17 indonesia buchi com www buchi com id in Japan Nihon BUCHI K K J...

Отзывы: