Faults
Causes
Solutions
TM
displayed on
ULTRAFEEDER
display
1) The motor temperature
exceeded the maximum
expected value.
1) Check the usage conditions of the systems.
If you cannot locate the cause of failure,
please contact your BTSR reseller (it could
be necessary to send the device to the
BTSR repair centre).
The machine is not
stopped by
ULTRAFEEDER in
case of yarn breakage
1) The third parameter of
P1
programming menu is
deactivated (OFF)
2) The Increment and Decrement
controls are not correctly
managed within the machine
program
3) The Stop function managed by
the machine and associated
with the ULTRAFEEDER
device has not been correctly
enabled within the machine
program.
4) Wiring problem
1) Check the correct programming of
ULTRAFEEDER parameters.
2) Check the machine program handling the INC-
DEC controls. The INC-DEC LEDs on KTF/PW4
power supply must be ON and the “P1” label
must be active.
3) Check the machine program handling the STOP
input and confirm that it is enabled when the yarn
fed by ULTRAFEEDER is in working condition.
4) If the stop led on ULTRAFEEDER and the
corresponding stop led on KTF/PW4 power
supply turn on, when the yarn breaks, check the
machine connecting cables.
To check the correct operation of the
ULTRAFEEDER’s STOP output press the
"Control
"
button that will turn on both
LEDs (front and rear); if this does not occur
please contact your BTSR reseller (it could
be necessary to send the device to the
BTSR repair centre).
OVERFLOW INC
or
UNDERFLOW DEC
displayed on
ULTRAFEEDER
display
1) Incompatibility between the
ULTRAFEEDER programming
and the number of
increments/decrements
generated by the machine
program
1) Check the ULTRAFEEDER programming, in
particular the INC-DEC tension parameters in
P1
,
and the machine program
(check the number of
increments/decrements required).
The ULTRAFEEDER
device does not
communicate with
SMART FEEDER
terminal
1) The identification code of
ULTRAFEEDER device is not
correct
2) Failure on SMART MATRIX
FEEDER/PFU terminal
3) Wiring problem
1) Check that the parameter corresponding to the
identification number
(parameter
P3.4
)
is correct;
if necessary carry out the numbering procedure
using the SMART MATRIX FEEDER/PFU
terminal or set directly the identification code on
KTF device
(parameter
P3.4
)
.
2) Check the correct operation of SMART MATRIX
FEEDER/PFU terminal using the numbering
procedure described in the SMART MATRIX
FEEDER/PFU manual.
3) Check the wiring starting from "SMART- IN"
connector on KTF/PW4 power supply and on
SMART MATRIX FEEDER/PFU terminal.
ASC1010 COM-ERROR
displayed on
ULTRAFEEDER
display
1) Missing communication
between main DSP and
loading cell DSP.
1) Reset the alarm; if the problem persists, contact
your BTSR reseller.
Содержание ULTRAFEEDER
Страница 1: ...ULTRAFEEDER YARN CONTROL SYSTEM Operating Manual ENGLISH Rev 4 1 February 2017 ...
Страница 40: ...Technical Data and Installation 2 28 ULTRAFEEDER Page intentionally left blank ...
Страница 72: ...ULTRAFEEDER Troubleshooting and Maintenance 4 6 ULTRAFEEDER Page intentionally left blank ...
Страница 78: ...YTT Device 5 6 ULTRAFEEDER Page intentionally left blank ...