3/15
ELIOT Kit Salvavita Connesso
Cat. N°: G723SC
3. OVERALL DIMENSIONS
(continued)
. Power supply module:
. Supply patch cord:
L = 250 mm
4. PREPARATION - CONNECTION
Fixing:
. On symmetric rail EN/IEC 60715 or DIN 35.
Operating positions:
. Vertical, Horizontal, backwards, on the side
Power Supply:
Primary voltage 95÷250 V~
Secondary voltage 12 Vd.c. 500 mA
. Power distribution towards the interface via specific 250 mm supply
patch cord (delivered with the kit) to connect at the downstream of the
supplier indifferently in one of the two dedicated ports
Supply of the Wi-Fi Interface:
. Mandatory in 12 V d.c. via the specific Power supply module and
specific supply patch cord 250 mm length (delivered with the kit) to
connect at the downstream through dedicated port
Supply of the Salvavita Connesso:
. Supply Phase and Neutral from the top on the extractable connector.
. It is mandatory to connect Phase and Neutral downstream of the
associated device and the protection conductor to the connector at the
bottom of this device. Salvavita Connesso will not work correctly if the
protection conductor is not connected.
Technical data sheet: IDP000172EN_01
Updated: -
Created: 08/09/2017
Connection cable to the
Salvavita Connesso