ELIOT Kit Salvavita Connesso

 

 

Cat. N°: G723SC 

 

 

1. DESCRIPTION - USE 

With a Smartphone, to remotely switch ON/OFF a circuit protected 
by a 1 module per pole BTDIN RCCB or RCBO up to 63 A. 

(not 

delivered with the kit). 

Must be used with the app “POWER ON” 

available on Google Play and Play Store. 
In case of unwanted tripping (temporarily electrical disturbances or 
other external events) and if no permanent fault is detected: it will 
send a message to the user in order to get an authorization to switch 
ON the associated device. 
In case of permanent fault: the user will be informed about it without 
having the possibility to remotely switch on the power. 

2. RANGE 

. Cat. n° G723SC: Eliot Kit “Salvavita Connesso”, composed by: 
Non-automatic resetting Salvavita Connesso (cat. no G723SC) 
. During a “normal situation”: 

- It permanently checks the status of the installation. 
- It allows the user to remotely switch ON/OFF the associated 
device 

. During an “unwanted tripping” due to a non permanent fault: 

- It reports the information through the Smartphone app 
- Allows the user to remotely switch it ON 
- In case of recurrent non permanent faults, the Salvavita 
Connesso will not allow some remote command 

(see details on page 

5)

 

. During an “unwanted tripping” due to a permanent fault (earth 
leakage or short circuit): 

- It reports the information through the Smartphone app 
- It does not allow the use to remotely switch On the device and 
advises to contact an electrician to check the installation. 

. Technology: DC electric motor with permanent magnets 
. 2 modules (35,6 mm) width 
. Rated Voltage & Frequency: 230 V ~ 50 / 60 Hz with standard 
tolerances. 
. Operating voltages: 
  Minimum (0,85 x Un): 195,5 V 
  Maximum (1,1 x Un): 253 V 

Wi-Fi  interface module (cat. no F80IIP) 
To communicate with the Smartphone through a Wi-Fi Box 
. 1 module (17,8 mm) width  
. Supplied by the Power supply module via supply patch cord  
. Equipped with a 1m length pre-cabled cable to connect with the 
Salvavita Connesso 

Supply patch cord: 
. Allows to connect the Power supply module with the Wi-Fi interface 
 at the downstream through dedicated connectors. 
. Length: 250 mm 
 

 

2. RANGE

 (continued)

 

Configuration & use: 

. Must be used with the app “POWER ON” 

  

. To be downloaded for free on Google Play or App Store 

 

 

All the configurations steps are explained in the app. 
Note: This part can be done without any ADSL Wi-Fi box thanks to the 
Wi-Fi module which allows to display its own network for this step. 

3. OVERALL DIMENSIONS 

. Salvavita Connesso 

 

. Wi-Fi interface module (already equipped with an external Half Wave 
2.4GHz Antenna With RP-SMA Connector): 

 

 

 

 

Technical data sheet: IDP000172EN_01 

Updated: - 

Created: 08/09/2017 

 

 

 

Содержание Salvavita Connesso G723SC

Страница 1: ...1 Description Use 2 2 Product range 2 3 Overall dimensions 2 4 Preparation Connection 3 5 General characteristics 8 6 System architecture 11 7 Conformities and approvals 12 8 Auxiliaries and accessor...

Страница 2: ...an unwanted tripping due to a permanent fault earth leakage or short circuit It reports the information through the Smartphone app It does not allow the use to remotely switch On the device and advis...

Страница 3: ...in one of the two dedicated ports Supply of the Wi Fi Interface Mandatory in 12 V d c via the specific Power supply module and specific supply patch cord 250 mm length delivered with the kit to connec...

Страница 4: ...e It is not necessary to install a specific protections upstream of the Salvavita Connesso because it is self protected 4 PREPARATION CONNECTION continued Wiring diagrams continued Power supply module...

Страница 5: ...on a different DIN row than the Salvavita Connesso module 4 PREPARATION CONNECTION continued On site information displayed by the Salvavita Connesso Salvavita Connesso lockout By the sliding front fac...

Страница 6: ...Salvavita Connesso continued Details for too recurrent non permanent faults During its functioning the Salvavita Connesso memorises the numbers of faults and consequent numbers of remote manual resett...

Страница 7: ...Fi module signalling led continued Wi Fi led indicates the status of the Wi Fi Network Possible states Led color State Meaning red Slow blinking No Wi Fi network detected or connection problems Fast b...

Страница 8: ...ACTERISTICS Salvavita Connesso marking Front side marking by permanent pad printing Terminals marking Upstream terminal block by permanent ink pad printing Downstream terminal block by permanent ink p...

Страница 9: ...ISTICS continued Wi Fi module marking Front side marking by permanent ink pad printing red line and laser marking Lateral side marking by laser left side Standard and others information right side tra...

Страница 10: ...endurance of Salvavita Connesso In accordance with the requirements of the standards of the associated protection device 5 GENERAL CHARACTERISTICS continued Plastic materials Self extinguishing polyc...

Страница 11: ...m of the associated device to the Salvavita Connesso and to protect the power supply module with a fuse holder or an MCB see Wiring diagrams Supply of the ADSL Wi Fi Box The Wi Fi module communicates...

Страница 12: ...s RCCBs for household and similar use EN 60898 1 2003 corr Feb 2004 A1 2004 A11 2005 A12 2008 Electrical accessories Circuit breakers for overcurrent protection for household and similar installations...

Страница 13: ...h can be modified to 2 auxiliary contacts 1 module F80CR Electronic EMS BTDIN Auxiliary contact Fault signalling module cat n F80BCR Control auxiliaries It is forbidden to associate control auxiliarie...

Страница 14: ...non permanent fault occurred Remote command allowed 4 Salvavita Connesso has been open manually Remote command not allowed Close manually the Salvavita Connesso 5 A too recurrent non permanent fault...

Страница 15: ...n MAN mode Remote command not allowed Put selector in AUTO position 8 Salvavita Connesso is in MAN mode Remote command not allowed Put selector in AUTO position 9 Salvavita Connesso in locked position...