STANDARD AUTOMATION MODE - Configurator SPE=1
CONFIGURATION
This mode of operation can implement the standard automation functions (e.g. control lights and rolling shutters).
Mode configurations (M1, M2):
a) M= — (no configurator)
:
operation in cyclical mode actuator ON/OFF. With quick press actuator ON/OFF, with long press
dimmer adjustment (only for point point command)*.
b) M=ON
: only ON command*.
c) M=OFF
: only OFF command*.
d) M= O/I
: with quick press actuator ON/OFF, with long press dimmer adjustment (only for point point command). The ON and
intensity adjustment UP commands are automatically associated with the upper key of the pair while the OFF and intensity
adjustment DOWN commands are associated with the lower key.
e) M=
⇑⇓
: rolling shutters UP and DOWN; up-down operation to limit switch in bistable mode. The UP command (UP for long press,
STOP for short press) is automatically associated with the upper key of the pair while the DOWN command (DOWN for long
press, STOP for short press) is associated with the lower key.
f) M=
⇑⇓
M
: rolling shutters UP and DOWN; up-down operation for the time the key is pressed (maximum 20 seconds) in monostable
mode. The UP command (UP for long press, STOP for short press) is automatically associated with the upper key of the pair
while the DOWN command (DOWN for long press, STOP for short press) is associated with the lower key. Releasing the key
sends a stop command.
g) M=PUL
: pushbutton mode*.
h) M=1-8
: timing (ON command timed).
The duration of the timing depends on the configurator value on the basis of the following table*:
i) M= CEN
: command for the scenario programmer.
Configurator
Nominal duration
1
1 min
2
2 min
3
3 min
4
4 min
5
5 min
6
15min
7
30s
8
0.5s
Room (A) and Light Point (PL1, PL2) configuration:
For mode a) to h):
-
A=1-9
: is the room of the command recipient for
point-point
command:
PL1, PL2=1-9
are the light points
for which the commands are intended
-
A=AMB
: for
room
commands;
PL1, PL2=1-9
are the rooms for which the commands are intended
-
A=GR
: for
group
commands;
PL1, PL2=1-9
are the groups for which the commands are intended
-
A=GEN
: for
general
commands;
PL1, PL2
must be
0
-
A=AUX
: for
auxiliary
commands;
PL2=1-9
while
M1, M2
must be different from
1-8
For mode i):
- A=1-9 and PL1=1-9
: determine the local address of the command.
The other configurators must be set to
M1=CEN
,
PL2=0
,
M2=CEN
A
4
PL1
1
M1
O/I
PL2
3
M2
⇑⇓
SPE
1
Example of configuration:
The following functions are obtained with the configuration to the side:
- the pair of keys 1-3 is configured with lights ON/OFF in O/I mode. Key 1 performs the
ON and the intensity adjustment UP while key 3 performs OFF and intensity adjustment
DOWN of the actuator with address 41;
- the pair of keys 2-4 is configured with rolling shutters UP/DOWN in bistable mode. Key 2
performs the UP while key 4 performs OFF and DOWN of the actuator with address 43.
If positions PL2 and M2 are not configured, the pair of keys 2/4 is disabled.
1
2
3
4
Mode M1 refers to pair
of keys 1-3
Mode M1 refers to pair
of keys 2-4
* For the modes in points a) b) c) g) and h) the spacer supplied
must be mounted on the back of the key cover, so that only
the lower key of the pair is used (see figure to the side).