register
RSH-EC_Cap_6_en
Rev. 1.0 - 02/2012
19
6.4 Electrical commissioning/start-up of the register sensor
Fig. 6.4
Perform the following operating steps:
Connect the voltage supply cable to direct current input
X3.
If you would like to connect additional register sensors:
Connect the voltage supply cable for the next register
sensor to direct current output X4.
Connect the bus cable coming from the register controller
or previous bus participant to connection X1 of the
register sensor.
If you would like to connect additional bus participants:
Connect the bus cable of the next bus participant to
output X2.
Connect the grounding cable (minimum cross section 4
mm²) to the equipotential bonding of the register sensor
(assembly order: screw, lock washer, washer, cable lug,
serrated lock-washer). When using the 2 channel version
of the register sensor: Repeat this operating step for the
second optical waveguide.
Finally, firmly screw all the cable connections to the
register sensor. Commissioning/start-up is carried out together with the
connected register controller system.
For a detailed description of the connection assignment
see
chapter 6.2.3 CONNECTION ASSIGNMENT.