Operation
7
19
ekr 500 web guiding controller
EDV No.: MD.299.01.06
Chapter: 7
with removable control panel
Date:
29.07.08
Page:
65/86
7. Remove material from sensor 2
(no material within the sensor scanning area).
The detected bright value is shown in the display.
8. Cover scanning area of sensor 2 with the material to be
scanned for at least 2 seconds.
The detected dark value is shown in the display.
9. Press key “
ENTER
“.
The detected bright and dark values for sensor 2 are stored.
The material setup is completed.
The operating screen is displayed.