Installation
5
13
ekr 500 web guiding controller
EDV No.: MD.299.01.06
Chapter: 5
with removable control panel
Date:
29.07.08
Page:
37/86
5.5.2.7 Terminal strip X10; Enable controller / Servo-center transducer OMG 8 (Namur) / Relay contact
Terminal
X10
Function
Wire colour
Remarks
51
OMG 8 (Namur A)
brown/black
52
OMG 8 (Namur B)
blue
53 GND
GND for enable actuator
54 +24
V
24 V
for enable actuator
55
Enable actuator
(controller interlock)
Input enable actuator.
Link to terminal 54 if not used.
56 Relay
–
closed contact
57 Relay
–
change-over contact
58 Relay
–
contact that opens
white (only EFE 1000)
The open contact is normally
closed when working correctly.
5.5.2.8 Terminal strip X14; Digital inputs, electronic remote precision adjustment EFE 1000
Terminal
X14
Function
Wire colour
EFE 1000
Remarks
72 GND
brown
73 GND
GND for inputs 0 ... 7
74 Input
0
75 Input
1
76 Input
2
77 Input
3
78 Input
4
79 Input
5
yellow*
80 Input
6
pink*
See truth table
(chapter 8)
81 Input
7
Link to terminal 82 to activate
the keyboard lock.
82
+24 V
Link to terminal 57
(X10).
83 +24
V
green
24 V
Max. 200 mA
*
The lines on terminals 79 and 80 must be swapped over to change
the EFE 1000 working direction.