Start-up
6
11
ekr 500 web guiding controller
EDV No.: MD.299.01.06
Chapter: 6
with removable control panel
Date:
29.07.08
Page:
45/86
6.1.2 Determine sense
of motor rotation
During start-up the assignment of the arrow keys to the actuating
direction (sense of motor rotation) of the actuator must be checked.
1. Press key “
Manual mode
“.
The controller changes to manual mode.
The LED of the key lights.
2. Press arrow key “
left
“ or “
right
“.
Observe guiding device!
When pressing arrow key “
left
“ the guiding device must move
towards
sensor 1
.
When pressing arrow key “
right
“ the guiding device must move
towards
sensor 2
.
If the guiding device moves in the opposite direction then the
motor connection lines on terminal strip
X7
(terminal
42
and
43
)
must be swapped over.
The assignment of the sensors (sensor 1 / sensor 2) is described
in chapter 1.5.2.
6.1.3 Determine guiding direction
During start-up the assignment of the selection buttons for the
guiding mode to the actuating direction (sense of motor rotation) of
the actuator must be checked.
1. Press key “
Sensor 1
“ or “
Sensor 2
“.
The selected guiding mode is active.
The LED of the key lights.
2. Press key “
Automatic
“.
The controller changes to automatic mode.
The LED of the key lights.
3. Cover scanning area of the selected sensor with material
(e.g. thick paper).
Observe guiding device!
If there is still material in the sensor scanning area then the
guiding device must move away from the selected sensor.
If the material is removed from the sensor scanning area then
the guiding device must move in the direction of the selected
sensor.
If the guiding device moves away from the selected sensor
whilst the material is being removed, then change position of
DIL switch
S4.1
on the processor board (see chapter 5.6.1).
or
or