- 115 -
PS-8810
DIGITAL SIGNAL PROCESSOR
•
Control Port:
External events can be either generated or monitored via this
port and used to control or signal some function within the
unit. Sixteen digital outputs, eight digital inputs, and eight
analogue inputs provide access to the unit. current-limited
voltages (+5V and +10V) are provided to power external
circuits
Digital Outputs:
These eight outputs p10V at 10mA as
configured by IQ software. These outputs can signal
either a specific event or can signal the gate status of the
input channels
Analogue Outputs:
These eight 0 to +10VDC inputs can be mapped to any
object in the box for control. Fader objects can be
mapped to allow remote control of a particular fader
Digital Inputs:
Eight switched inputs can be linked to specific
functions, such as muters, in the unit. These inputs can
also be used to select a particular Preset based upon a
desired switch combination on these inputs. The inputs
are current driven and will accept any DC voltage to
+25VDC
Analogue Inputs:
Any fader in the unit can be controlled via one of these
inputs. A 10VDC swing allows the control to vary from
null to full scale. IQ software controls provide limiting of
the fader value in the unit
Technical Information
Содержание Prosys PS-8810
Страница 1: ...PS 8810 Digital Signal Processor Connect here first User Manual ...
Страница 12: ... 12 PS 8810 DIGITAL SIGNAL PROCESSOR ...
Страница 16: ... 16 PS 8810 DIGITAL SIGNAL PROCESSOR Controls Connectors Indicators ...
Страница 88: ... 88 PS 8810 DIGITAL SIGNAL PROCESSOR CobraNet ...
Страница 96: ... 96 PS 8810 DIGITAL SIGNAL PROCESSOR External Control ...
Страница 102: ... 102 PS 8810 DIGITAL SIGNAL PROCESSOR PS8810 IR Code Format ...
Страница 111: ... 111 PS 8810 DIGITAL SIGNAL PROCESSOR Reference Section ...
Страница 116: ... 116 PS 8810 DIGITAL SIGNAL PROCESSOR 19 0 Block Diagram ...
Страница 120: ... 120 PS 8810 DIGITAL SIGNAL PROCESSOR 21 0 User Notes ...
Страница 121: ... 121 PS 8810 DIGITAL SIGNAL PROCESSOR User Notes ...