Service and maintenance of machine
154
Verti-Mix 951-1651, Verti-Mix 951 L-1251 L, Verti-Mix 1501 D-2401 D 10.13
CAUTION
Risk of damage to machine components when powering
gearboxes without gear lubricant oil!
Always ensure a sufficient oil level in the gearboxes.
WARNING
Risk of slipping to people due to leaking oil during topping-up of
oil / oil change!
Immediately remove fresh oil stains by means of binding agents.
Change the oil when the gear lubricant oil has reached its
operating temperature (30-40°C) if possible. The flowability of
the gear lubricant oil is at its optimum at operating temperature.
The optimum oil level is reached at an oil temperature of 0-20°C.
12.5.1 Quantities when filled and change intervals
Change the gear lubricant oil:
for the first time after 1000 service hours,
o
then every 2000 service hours,
Dispose of used oil according to regulations. Contact your oil
supplier in case of disposal problems!
Gearbox
Quantity when filled
[litre]
Interval
Mixer gearbox
VM 951(L);VM1251(L); VM 1501 D; VM 1801 D;
VM 2401 D
20
After 1000 service hours,
than every 2000 service
hours
Mixer gearbox
VM 1651
28
Switchgear
13
Gearbox, on-board hydraulic system without
switchgear
0.75
Tab. 14