opened during pickling to prevent the pickling medium penetrating the packing area. Flushing should be 
done with the valve half-shut to facilitate thorough flushing of the internal surfaces. 
 
 

5.3.  Venting 

 

In accordance with the relevant Accident Prevention Regulations (UVV) valves and fittings should be 
vented by means of specially fitted vent pipes or stuffing box connections. Venting by slackening off the 
bonnet flange or the stuffing box gland is not permitted and can cause danger. If vents are required as 
non standard extra, we recommend that these be fitted in our works. 

 

5.4.  Heating and cooling rates 

 
To avoid damaging the valve body material or flange connections the normal plant-related heating and 
cooling rates must be observed. If in doubt, consult us (see chapter 4.3) 
 

5.5.  Additional operating rules 

 

Manual shut-off valves are right-hand or clockwise shutting. Back gears and remote drives are designed to 
retain this direction of rotation. Because valves are frequently subjected to high temperatures and develop 
surface and radiated heat as a result, protective clothing (especially gloves) should be worn. This is also 
recommended when operating valves where leaks can allow hazardous media (e.g. steam, acids) to 
escape. Hand wheels of electric actuators are for emergency operation only; they are disengaged during 
normal operations and can be engaged when required. 
 

Attention

 ! 

Valves with hand wheel  must only ever be manually operated. The use of bars or pipes to 

increase leverage can damage the unit and cause an accident through slippage or failure, and is 
not permitted. 

 
Where bypasses or drain valves are fitted to prevent temperature shocks to piping downstream or for 
other reasons, these secondary fittings must be operated before the main valve. For setting, maintenance 
and operation of actuators, refer to the manufacturer's instruction manual. 
 

5.6.  Function testing 

 

After installation, the valve must be function tested prior to initial operation. The valve, whether manually 
operated or driven, should be opened and shut at least once. 

 

5.7.  Checking during and after first operation 

 

During operation the tightness of the stuffing box and bonnet flange as well as the pipe connection flanges 
must be monitored. If necessary bolts should be further tightened (see points 3.7 and 4.1). Left 
unattended, leaks can cause erosion of the seal faces and seals and hence lead to permanent leakage. 
Seal tightness should be checked after a while since seals and bolts etc.. are apt to settle during initial 
operation, especially at high temperatures. 
 
 
 

Содержание ROFI

Страница 1: ...e transport and storage 7 3 1 Transport 7 3 2 Storage 7 4 Details on safe installation 7 4 1 Planning and installation 8 4 1 1 Installing position 9 4 1 2 Spindle operated Valves 9 4 1 3 Non return Va...

Страница 2: ...2015 2 16 by ROFI S A R L Content Page 5 7 Checking during and after first operation 12 6 Maintenance 13 6 1 Gland packing Bonnet flange seals and Replacement 13 6 2 Recommended lubricants 14 6 3 Lubr...

Страница 3: ...peration load stressing disintegration pressure of unstable fluorides etc If the purchaser expects stresses deviating from the normal operating conditions he has to indicate these requirements unambig...

Страница 4: ...sonnel 2 General Information The design of the valve depends upon the use and is beneath the responsibility of the buyer With the application for mediums and temperatures which differ from the type de...

Страница 5: ...rective 94 9 EG with the EX mark we declare the conformity with the ATEX Directive 94 9 EG for the use in hazardous areas 2 2 Notes on possible dangers 2 2 1 Significance symbols and explanatory notes...

Страница 6: ...be used with fluids which doesn t cause any explosive mixture or atmosphere in the interior Attention Refer to the data sheet for applications limits on use and possibilities Certain media require or...

Страница 7: ...ns 3 2 Storage On site the valves must be stored so as to be protected against mechanical damage and or corrosion The preferable storage condition is in closed rooms with ambient temperature Flanges o...

Страница 8: ...alings are centred at the joining flanges The pipe relaying is to be done in such a way that harmful thrusts and bending stresses will be kept away from the body While coating the plant gland bolt nut...

Страница 9: ...ng device which are fitted in a non horizontal piping it should be assured by reconstruction that the closing or damping device action is not disturbed Swing check valves with outside control mechanis...

Страница 10: ...re machining chips and other foreign matter must be carefully removed The pipe ends must be properly aligned so as to prevent the valve being subjected to unnecessary strain Bricklaying or painting sh...

Страница 11: ...he specific torques of electric actuators normally are set in the factory The closing of ROFI valves is controlled by torque switches eventually additionally secured by limit switches Opening of the v...

Страница 12: ...worn This is also recommended when operating valves where leaks can allow hazardous media e g steam acids to escape Hand wheels of electric actuators are for emergency operation only they are disengag...

Страница 13: ...he position of the valve within the plant configuration the medium operating cycle temperature change loadings and so forth The user should call upon his experience as plant operator to specify inspec...

Страница 14: ...ration cycle its ambient conditions pollution temperature and the influence of the valve heat on the grease point The spindle thread should first be cleaned if heavily soiled and the gland area protec...

Страница 15: ...e size or material Re grind seats use spare parts only by qualified personnel Leaks through Bonnet and Flange Extreme temperature fluctuation or vibration Excessive pressure stresses on the Bonnet Fla...

Страница 16: ...ase Order Number under which the valve was first supplied 9 Guarantee Warranty The extent and period of warranty cover are specified in the Standard Terms and Conditions of ROFI S A R L valid at the t...

Отзывы: