6
STEP 3 - Connect the battery charger to Mains Power (240Vac)
Connect the battery charger to a 240VAC Mains Powered socket.
The Charger will automatically start when AC power is connected and switched on.
(Note: If the Fault Indicator LED illuminates Red, please check your connections as it’s likely that
the Positive and Negative Leads are reversed. Refer to Trouble Shooting Page for further
information)
THE CHARGING PROCESS:
The charging stages are as follows:
NORMAL CHARGING MODE
:
All Led will light ON a second when A.C. Power is on. It goes to the NORMAL Charging Mode
automatically.
There are 3 stages:
o
Bulk Charging Mode (C.C. Mode)
Charging Green LED is flashing.
The battery can be charged about 80%.
The charger delivers an almost constant current 2A until the battery voltage reaches
the set value.
o
Absorption Mode (C.V. Mode)
Charging Green LED is flashing.
The battery can charge up to almost 100%.
The charging current tapers and the charging voltage are kept constant at the set
value.
o
Maintenance Mode (Float Mode)
Charging Green LED is on continuously.
The Float Mode allows the charger to effectively be left connected to your batteries,
over the course of a season, without overcharging your batteries, and maintains your
battery in a good condition if it is not being used.