background image

 

 

 

BATTERY TYPES & CAPACITY:

 

 

Suits all Lead Acid Type Batteries. (Conventional, AGM & Gel) 

 

Able to charge either Lead Acid or Gel Batteries: 

o

 

Before  you  plug  in  AC  power  and  connect  battery  clamp  to  the  battery,  you  must 
select either LEAD-ACID or GEL mode with the LEAD-ACID/GEL slide switch 

 

12 Volt Output 

 

Charge Current: 2A 

 

Battery Capacity: 

 

The following maximum AH capacities are to be used as a general guide 

only: some batteries maybe able to handle a higher Charge Current. Check with the battery 
Manufacturer when charging batteries with small capacity.

 

 

Charge Current 

2A 

Battery Capacity: Charging 

4-80AH 

Battery Capacity: Maintaining 
 

4-120 AH 

 

ELECTRICAL PARTS: 

Delivered with: 

 

A.C Power Cord: 

o

 

6 feet with VDE Plug 

 

Output Lead: 

o

 

4 feet with Trailer Connector  

 

Extension Cord:  

o

 

2 feet with Trailer Con Battery Clamp 

or

 

o

 

2 feet with Trailer Con Ring Connector 

 

ENVIRONMENTAL CHARACTERISTICS: 

 

Operating Temperature: 0 to 40° C 

 

Storage Temperature: -10 to 80°C 

 

Operating Humidity Range: 90% RH Max 

 

TECHNICAL SPECIFICATIONS: 

 

 

 

 

 

 

 

Part Number 

BS20 

Type 

Smart 

Input Voltage Range 
 

100-240Vac 

Input Frequency 

50/60Hz 

Output 

2A @ 12V 

Size (L*W*H) in mm 
 

140*65*42 

Weight 

0.45Kg 

Approvals 

CE, UL/cUL, Mzs, As 

Содержание BS20

Страница 1: ...GER For lead acid batteries User Manual and Guide to professional battery charging for Starter and Deep Cycle batteries THIS MANUAL CONTAINS IMPORTANT SAFETY AND OPERATING INSTRUCTIONS FOR 12V BATTERY CHARGER BS20 ENGLISH ...

Страница 2: ...attery while charging Be extra cautious to reduce risk of dropping a metal tool onto battery It might spark or short circuit battery or other electrical part that may cause explosion When working with a lead acid battery remove personal metal items such as rings bracelets necklaces watches NEVER smoke or allow a spark or flame in vicinity of battery or engine Do not charge non rechargeable batteri...

Страница 3: ...ad electronic circuit When the charger is overheated the charger will shut down shortly If temperature is decreased the charger will resume to normal charging OVERLOAD PROTECTION The charger employs the use of a Solid State Circuit Interrupter that opens under severe overload This condition may occur if attempting to charge any severely discharged or heavily sulfated battery Once the Interrupter o...

Страница 4: ...y Manufacturer when charging batteries with small capacity Charge Current 2A Battery Capacity Charging 4 80AH Battery Capacity Maintaining 4 120 AH ELECTRICAL PARTS Delivered with A C Power Cord o 6 feet with VDE Plug Output Lead o 4 feet with Trailer Connector Extension Cord o 2 feet with Trailer Connector Battery Clamp or o 2 feet with Trailer Connector Ring Connector ENVIRONMENTAL CHARACTERISTI...

Страница 5: ...the Battery charger to your Battery If the Battery is out of the vehicle o Connect the Red lead from the charger to the positive battery terminal o Connect the Black lead from the charger to the negative battery terminal If the Battery is still in the vehicle determine if the vehicle is positively or negatively earthed o If Negatively Earthed Most Common FIRST Connect the Red battery charger lead ...

Страница 6: ...es to the NORMAL Charging Mode automatically There are 3 stages o Bulk Charging Mode C C Mode Charging Green LED is flashing The battery can be charged about 80 The charger delivers an almost constant current 2A until the battery voltage reaches the set value o Absorption Mode C V Mode Charging Green LED is flashing The battery can charge up to almost 100 The charging current tapers and the chargi...

Страница 7: ...e up to almost 100 The charging current tapers and the charging voltage is kept constant at the set value o Maintenance Mode Float Mode The Float Mode allows the charger to effectively be left connected to your batteries over the course of a season without overcharging your batteries and maintains your battery s full charge The Float Mode also contains a special charging waveform that pulses power...

Страница 8: ...witched ON LED Status Descriptions Power LED RED Red ON AC Power is connected Red Flash Short Circuit or Polarity Reversed Recovery LED YELLOW RED Yellow Red Alternative Flash Battery Recovery mode is in progress Red ON Battery Recovery Fail Charging LED GREEN Green Flash Bulk Charging CC Mode Absorption Mode CV Mode Green ON The charger is at Float mode Full CHARGING CURVE VOLTAGE Power LED Recov...

Страница 9: ...ated Battery has a damaged cell Overheat protection mode Check the Battery condition age etc Battery may need replacement Move battery Charger to cooler environment Long charging time Full light does not come on Error RED LED is Flashing Battery capacity too large Battery is defective Check the charger specification matches the battery capacity Battery cannot be charged and must be replaced MAINTE...