background image

916SA: Product Data

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

9

NOTE: 

1. A filter is required for each return-air inlet. Airflow performance included 3/4-in. (19 mm) washable filter media such as contained in a factory - authorized accessory filter rack. See 

accessory list. To determine airflow performance without this filter, assume an additional 0.1 in. w.c. available external static pressure.

2. Adjust the blower airflow setting as necessary for the proper air temperature rise for each installation.

3. Airflows over 1800 CFM require bottom return, two-side return, or bottom and side return. A minimum filter size of 20” x 25” (508 x 635 mm) is required.

4. For upflow applications, air entering from one side into both the side of the furnace and a return air base counts as a side and bottom return

5. The -- entry indicates unstable operating conditions

66120M24

1

Cont. Fan

720

610

490

390

290

205

110

-

-

-

2

800

695

590

480

390

300

220

135

-

-

3

870

770

675

570

475

395

310

235

155

-

4

970

880

785

700

605

525

440

365

290

230

5

1060

975

890

805

725

635

555

485

410

345

6

1145

1070

985

905

830

750

665

595

525

455

7

1250

1175

1105

1025

955

880

805

730

660

595

8

1345

1280

1205

1135

1065

1000

930

860

785

725

9

1435

1370

1305

1240

1170

1105

1045

980

910

845

10

1545

1485

1425

1360

1300

1235

1175

1115

1050

990

11

1645

1590

1530

1475

1415

1350

1295

1240

1180

1125

12

1740

1685

1635

1580

1525

1465

1410

1355

1300

1250

13

1830

1775

1725

1675

1620

1565

1510

1455

1405

1355

14

Heat

2015

1965

1920

1870

1825

1775

1725

1680

1630

1580

15

2035

1990

1940

1895

1850

1805

1760

1710

1660

1615

16

2140

2095

2050

2005

1960

1915

1875

1830

1785

1740

17

2230

2190

2150

2110

2070

2025

1985

1945

1905

1860

18

Cooling

2425

2385

2340

2290

2240

2190

2135

2080

2025

1965

66140M24

1

Cont. Fan

795

685

585

475

380

290

205

135

-

-

2

900

795

700

605

505

420

340

260

180

-

3

960

865

775

685

590

500

420

345

265

195

4

1050

960

870

785

700

610

530

455

385

315

5

1160

1075

985

910

835

755

670

590

525

455

6

1260

1180

1100

1020

950

880

800

720

650

585

7

1355

1285

1205

1130

1060

995

925

855

775

705

8

1445

1375

1300

1230

1160

1095

1035

970

895

825

9

1545

1480

1415

1345

1280

1220

1155

1095

1035

965

10

1650

1585

1520

1460

1395

1330

1275

1215

1155

1100

11

1740

1680

1620

1560

1500

1435

1380

1320

1265

1210

12

1840

1785

1725

1670

1615

1555

1500

1445

1390

1340

13

1940

1885

1830

1775

1720

1670

1610

1555

1505

1450

14

2050

1995

1945

1890

1840

1790

1735

1680

1630

1575

15

Heat

2095

2040

1990

1940

1890

1840

1790

1735

1680

1630

16

2150

2100

2050

2000

1950

1905

1855

1800

1745

1695

17

2255

2205

2155

2110

2060

2015

1965

1915

1860

1810

18

Cooling

2420

2370

2325

2280

2230

2165

2095

2025

1955

1880

Air Delivery - CFM (with filter) (Continued)

Unit Size

Airflow 

Setting

Default 

Setting

External Static Pressure (IN.W.C.)

0.1

0.2

0.3

0.4

0.5

0.6

0.7

0.8

0.9

1

Airflow Settings

Default Airflow Settings

*

*. Setting #1 is the default setting for Constant Fan

Designated Airflow Settings

Unit Size

Heating

Cooling

Heating 

Constant Fan

30026M14

6

18

(5-14)

(1-7)

30040M14

9

18

(6-11)

(1-1)

36040M17

8

18

(5-9)

(1-5)

36060M14

12

18

(9-12)

(1-3)

48060M17

9

18

(5-10)

(1-7)

48080M17

12

18

(7-13)

(1-1)

60080M21

9

17

(5-11)

(1-8)

60100M21

12

18

(10-12)

(1-4)

66100M21

11

17

(8-14)

(1-7)

66120M24

14

18

(11-14)

(1-3)

66140M24

15

18

(10-15)

(1-1)

Содержание Legacy 95 916SA

Страница 1: ...ing operation when installed with a matched air conditioner or heat pump Adjustable blower speed for heating and cooling Aluminized steel primary heat exchanger Stainless steel condensing secondary he...

Страница 2: ...361 12 1 2 319 12 9 16 322 7 1 8 181 123 56 36040M17 17 1 2 445 15 7 8 403 16 406 8 3 4 222 130 59 36060M14 14 3 16 361 12 1 2 319 12 9 16 322 7 1 8 181 129 59 48060M17 17 1 2 445 15 7 8 403 16 406 8...

Страница 3: ...e furnace and resulting failure damage or repairs may impact warranty coverage 1 Heat Exchanger 9 2 Tier NOx 8 3 AFUE NOx 7 4 Heating Stages M 5 Major Series B 6 7 Cooling Capacity CFM 42 8 10 Heat In...

Страница 4: ...he factory specified 4 5 16 in 110 mm wide high efficiency media filter Heating 620 705 700 945 1030 1290 Cooling 175 970 155 1000 160 1075 200 1165 315 1580 370 1625 Direct Drive Motor HP 1 3 1 2 1 2...

Страница 5: ...y specified 4 5 16 in 110 mm wide high efficiency media filter Heating 1310 1730 1710 1965 2040 Cooling 225 2125 375 2145 450 2240 290 2240 380 2230 Direct Drive Motor HP 1 1 1 1 1 Motor Full Load Amp...

Страница 6: ...530 485 440 395 350 300 255 205 155 6 565 525 485 440 400 355 310 270 220 170 7 600 560 520 480 440 400 360 320 275 230 8 645 605 570 530 495 455 415 375 335 300 9 Heat 705 665 630 595 560 525 490 45...

Страница 7: ...0 650 10 1095 1055 1015 975 935 895 855 815 775 730 11 1165 1130 1090 1050 1010 975 940 900 865 830 12 1235 1200 1160 1125 1090 1055 1020 985 945 915 13 1315 1280 1245 1210 1175 1140 1110 1075 1045 10...

Страница 8: ...375 1325 1275 1220 1170 1115 1060 1010 10 1565 1520 1470 1425 1375 1330 1280 1230 1175 1125 11 1675 1625 1580 1535 1490 1450 1400 1355 1305 1255 12 Heat 1755 1710 1665 1625 1580 1535 1490 1450 1405 13...

Страница 9: ...1870 1825 1775 1725 1680 1630 1580 15 2035 1990 1940 1895 1850 1805 1760 1710 1660 1615 16 2140 2095 2050 2005 1960 1915 1875 1830 1785 1740 17 2230 2190 2150 2110 2070 2025 1985 1945 1905 1860 18 Co...

Страница 10: ...1 2 1 2 1 2 20 20 20 50 45 60 50 0 5 5 25 20 30 25 20 15 10 20 15 40 10 5 15 10 Winter Design Temp F Unit Size 40 000 BTUH 60 000 BTUH Uninsulated 3 8 in Insulation 1 2 in Insulation Uninsulated 3 8 i...

Страница 11: ...0 1 5 4 6 4 6 3 0 1 5 6 1 4 6 4 6 3 0 6 1 6 1 4 6 3 0 Winter Design Temp C Unit Size 80 000 BTUH Uninsulated 3 8 in Insulation 1 2 in Insulation Pipe Dia mm 38 51 64 76 102 38 51 64 76 102 38 51 64 76...

Страница 12: ...00 40 155 185 20 100 175 200 15 55 130 175 200 20 80 175 200 10 75 185 5 65 155 2001 3000 65 190 35 150 175 95 165 185 10 49 125 165 185 15 75 165 185 70 175 N A 60 140 3001 4000 60 175 30 135 160 16...

Страница 13: ...g radius elbows use the highest number of elbows for either the vent or inlet pipe 3 x 3 ft 0 9 M 9 ft 2 7 M From Deductions from Maximum Equivalent Vent Length Ft M Table Add equiv length of 2 45 lon...

Страница 14: ...ow applications POSITION CLEARANCE Rear 0 0 mm Front Combustion air openings in furnace and in structure 1 in 25 mm Required for service Consult your local building codes 24 in 610 mm Recommended All...

Страница 15: ...le Offset X X X X X KGADA0301ALL Coil Adapter Kits Double Offset X X X X X KGARP0301B14 Return Air Base Upflow Applications 14 0 in wide X X X KGARP0301B17 Return Air Base Upflow Applications 17 5 in...

Страница 16: ...KGAVT0701CVT Vent Terminal Concentric 2 51 mm See Venting Tables KGAVT0801CVT Vent Terminal Concentric 3 76 mm KGAVT0101BRA Vent Terminal Bracket 2 51 mm KGAVT0201BRA Vent Terminal Bracket 3 76 mm KGA...

Страница 17: ...ter 20 508 mm MERV 8 FILXXCAR0020 X Cartridge Media Filter 20 508 mm MERV11 FILXXCAR0120 X Cartridge Media Filter 24 610 mm MERV 8 FILXXCAR0024 X Cartridge Media Filter 24 610 mm MERV11 FILXXCAR0124 X...

Отзывы: