916SA: Product Data
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
5
UNIT SIZE
60080M21
60100M21
66100M21
66120M24
66140M24
HEATING AND CAPACITY AND EFFICIENCY
Input BTUh
*
*. Gas input ratings are certified for elevations to 2000 ft. (610 M). In USA, For elevations above 2000 ft (610 M), reduce ratings 4 percent for each 1000 ft (305 M) above sea
level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 Table F.4 or furnace installation instructions.
80,000
100,000
100,000
120,000
140,000
Output Capacity (BTUh)
†
)
†. Capacity in accordance with U.S. Government DOE test procedures.
78,000
97,000
97,000
116,000
135,000
Certified Temperature Rise Range - °F (°C)
40-70
(22-39)
40-70
(22-39)
40-70
(22-39)
40-70
(22-39)
45-75
(25-42)
AFUE
Upflow/Hz
96.2%
96.2%
96.2
96.1
95%
Downflow
95%
95%
95%
95%
95%
AIRFLOW CAPACITY AND BLOWER DATA
Rated Certified External Static
Pressure
Heating
0.12
0.15
0.15
0.20
0.20
Cooling
0.50
0.50
0.50
0.50
0.50
Airflow CFM @ Rated ESP (CFM)
‡
‡. Airflow shown is for bottom only return-air supply for the as-shipped speed tap. For air delivery above 1800 CFM, see Air Delivery table for other options. A filter is required
for each return-air supply. An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16-in. (110 mm) wide, high efficiency media filter.
Heating
1310
1730
1710
1965
2040
Cooling
225-2125
375-2145
450-2240
290-2240
380-2230
Direct Drive Motor HP
1
1
1
1
1
Motor Full Load Amps
11.5
11.7
11.0
11.5
11.7
Heating Blower Control (Htg OFF-Delay)
Adjustable: 90, 120 (factory-set), 150, 180 seconds
Cooling Blower Control (Clg OFF-Delay)
Adjustable: 90 (factory-set), 5, 30 seconds
Blower Wheel Diameter x Width - In. (mm)
11x10
(279x254)
11x10
(279x254)
11x10
(279x254)
11x11
(279x279)
11x11
(279x279)
Air Filtration System
Field Supplied Filter
Filter used for Certified Watt Data
325531-40
**
**. See Accessory List for part numbers available.
ELECTRICAL DATA
Unit Volts-Hertz-Phase
115-60-1
Operating Voltage Range
Min-Max
104-127
Maximum Unit Amps
13.1
12.6
12.5
13.2
12.6
Unit Ampacity
17.3
16.7
16.5
17.4
16.7
Maximum Wire Length (Measure 1 way in Ft/M)
33/10.1
34/10.5
34/10.6
33/10.0
34/10.5
Minimum Wire Size
AWG
14
14
14
14
14
Max. Fuse/Ckt Bkr Size
(Time-Delay Type Recommended)
Amps
15
15
15
15
15
Transformer Capacity (24 VAC output)
40VA
External Control Power Available
Heating
12VA
Cooling
35VA
GAS CONTROLS
Burners
4
5
5
6
7
Gas Connection Size
1/2 in. NPT
Gas Valve (Redundant)
Mfr
White Rodgers™
Min. inlet pressure
(in.w.c.)
4.5 (Natural Gas)
Max. inlet pressure
(in.w.c.)
13.6 (Natural Gas)
Ignition Device
Silicon Nitride
Factory installed orifice
Size 44
CONNECTIONS
Communication System
None
Thermostat Connections
G, C, W, Y, R
Accessory Connections
EAC-1 (115 VAC); HUM (24 VAC); 1-STG AC (via Y)