916SA: Product Data
Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.
4
SPECIFICATIONS
UNIT SIZE
30026M14
30040M14
36040M17
36060M14
48060M17
48080M17
HEATING AND CAPACITY AND EFFICIENCY
Input BTUh
*
*. Gas input ratings are certified for elevations to 2000 ft. (610 M). In USA, For elevations above 2000 ft (610 M), reduce ratings 4 percent for each 1000 ft (305 M) above sea
level. Refer to National Fuel Gas Code NFPA 54/ANSI Z223.1 Table F.4 or furnace installation instructions.
26,000
40,000
40,000
60,000
60,000
80,000
Output Capacity (BTUh)
†
)
†. Capacity in accordance with U.S. Government DOE test procedures.
25,000
39,000
39,000
56,000
58,000
78,000
Certified Temperature Rise Range - °F (°C)
25-55
(14-31)
40-70
(22-39)
40-70
(22-39)
35-65
(19-36)
40-70
(22-39)
40-70
(22-39)
AFUE
Upflow/Hz
96.0%
96.0%
96.2%
95.0%
96.2%
96.2%
Downflow
95%
95%
95%
95%
95%
95%
AIRFLOW CAPACITY AND BLOWER DATA
Rated Certified External
Static Pressure
Heating
0.10
0.10
0.10
0.12
0.12
0.12
Cooling
0.50
0.50
0.50
0.50
0.50
0.50
Airflow CFM @ Rated ESP
(CFM)
‡
‡. Airflow shown is for bottom only return-air supply for the as-shipped speed tap. For air delivery above 1800 CFM, see Air Delivery table for other options. A filter is required
for each return-air supply. An airflow reduction of up to 7 percent may occur when using the factory-specified 4-5/16-in. (110 mm) wide, high efficiency media filter.
Heating
620
705
700
945
1030
1290
Cooling
175-970
155-1000
160-1075
200-1165
315-1580
370-1625
Direct Drive Motor HP
1/3
1/2
1/2
1/2
3/4
3/4
Motor Full Load Amps
4.4
6.3
6.7
6.3
8.8
9.2
Heating Blower Control (Htg OFF-Delay)
Adjustable: 90, 120 (factory-set), 150, 180 seconds
Cooling Blower Control (Clg OFF-Delay)
Adjustable: 90 (factory-set), 5, 30 seconds
Blower Wheel Diameter x Width - In. (mm)
11x7
(279x178)
11x7
(279x178)
11x8
(279x203)
11x7
(279x178)
11x8
(279x203)
11x8
(279x203)
Air Filtration System
Field Supplied Filter
Filter used for Certified Watt Data
325531-40
**
**. See Accessory List for part numbers available.
ELECTRICAL DATA
Unit Volts-Hertz-Phase
115-60-1
Operating Voltage Range
Min-Max
104-127
Maximum Unit Amps
5.2
7.0
7.4
7.1
10.1
10.0
Unit Ampacity
7.5
9.7
10.2
9.8
13.6
13.4
Maximum Wire Length (Measure 1 way in Ft/M)
50/15.2
38/11.7
36/11.1
38/11.5
27/8.3
27/8.4
Minimum Wire Size
AWG
14
14
14
14
14
14
Max. Fuse/Ckt Bk Size
(Time-Delay Type
Recommended)
Amps
15
15
15
15
15
15
Transformer Capacity (24 VAC output)
40VA
External Control Power
Available
Heating
12VA
Cooling
35VA
GAS CONTROLS
Burners
2
2
3
3
4
4
Gas Connection Size
1/2 in. NPT
Gas Valve (Redundant)
Mfr
White Rodgers™
Min. inlet pressure
(in.w.c.)
4.5 (Natural Gas)
Max. inlet pressure
(in.w.c.)
13.6 (Natural Gas)
Ignition Device
Silicon Nitride
Factory installed orifice
Size 44
CONNECTIONS
Communication System
None
Thermostat Connections
G,C, W, Y, R
Accessory Connections
EAC-1 (115 VAC); HUM (24 VAC); 1-STG AC (via Y)