background image

916SA: Product Data

Manufacturer reserves the right to change, at any time, specifications and designs without notice and without obligations.

2

A210796

Dimensional Drawing

Dimensions

FURNACE SIZE 

A

B

C

D

SHIP WT.

LB (KG)

CABINET WIDTH

OUTLET WIDTH

BOTTOM INLET WIDTH

AIR INTAKE

30026M14

14-3/16 (361)

12-1/2 (319)

12-9/16 (322)

7-1/8 (181)

119 (54)

30040M14

14-3/16 (361)

12-1/2 (319)

12-9/16 (322)

7-1/8 (181)

123 (56)

36040M17

17-1/2 (445)

15-7/8 (403)

16 (406)

8-3/4 (222)

130 (59)

36060M14

14-3/16 (361)

12-1/2 (319)

12-9/16 (322)

7-1/8 (181)

129 (59)

48060M17

17-1/2 (445)

15-7/8 (403)

16 (406)

8-3/4 (222)

142 (64)

48080M17

17-1/2 (445)

15-7/8 (403)

16 (406)

8-3/4 (222)

150 (68)

60080M21

21 (533)

19-3/8 (492)

19-1/2 (495)

10-1/2 (267)

158 (72)

60100M21

21 (533)

19-3/8 (492)

19-1/2 (495)

10-1/2 (267)

167 (76)

66100M21

21 (533)

19-3/8 (492)

19-1/2 (495)

10-1/2 (267)

167 (76)

66120M24

24-1/2 (622)

22-7/8 (581)

23 (584)

12-1/4 (311)

181 (82)

66140M24

24-1/2 (622)

22-7/8 (581)

23 (584)

12-1/4 (311)

189 (86)

Содержание Legacy 95 916SA

Страница 1: ...ing operation when installed with a matched air conditioner or heat pump Adjustable blower speed for heating and cooling Aluminized steel primary heat exchanger Stainless steel condensing secondary he...

Страница 2: ...361 12 1 2 319 12 9 16 322 7 1 8 181 123 56 36040M17 17 1 2 445 15 7 8 403 16 406 8 3 4 222 130 59 36060M14 14 3 16 361 12 1 2 319 12 9 16 322 7 1 8 181 129 59 48060M17 17 1 2 445 15 7 8 403 16 406 8...

Страница 3: ...e furnace and resulting failure damage or repairs may impact warranty coverage 1 Heat Exchanger 9 2 Tier NOx 8 3 AFUE NOx 7 4 Heating Stages M 5 Major Series B 6 7 Cooling Capacity CFM 42 8 10 Heat In...

Страница 4: ...he factory specified 4 5 16 in 110 mm wide high efficiency media filter Heating 620 705 700 945 1030 1290 Cooling 175 970 155 1000 160 1075 200 1165 315 1580 370 1625 Direct Drive Motor HP 1 3 1 2 1 2...

Страница 5: ...y specified 4 5 16 in 110 mm wide high efficiency media filter Heating 1310 1730 1710 1965 2040 Cooling 225 2125 375 2145 450 2240 290 2240 380 2230 Direct Drive Motor HP 1 1 1 1 1 Motor Full Load Amp...

Страница 6: ...530 485 440 395 350 300 255 205 155 6 565 525 485 440 400 355 310 270 220 170 7 600 560 520 480 440 400 360 320 275 230 8 645 605 570 530 495 455 415 375 335 300 9 Heat 705 665 630 595 560 525 490 45...

Страница 7: ...0 650 10 1095 1055 1015 975 935 895 855 815 775 730 11 1165 1130 1090 1050 1010 975 940 900 865 830 12 1235 1200 1160 1125 1090 1055 1020 985 945 915 13 1315 1280 1245 1210 1175 1140 1110 1075 1045 10...

Страница 8: ...375 1325 1275 1220 1170 1115 1060 1010 10 1565 1520 1470 1425 1375 1330 1280 1230 1175 1125 11 1675 1625 1580 1535 1490 1450 1400 1355 1305 1255 12 Heat 1755 1710 1665 1625 1580 1535 1490 1450 1405 13...

Страница 9: ...1870 1825 1775 1725 1680 1630 1580 15 2035 1990 1940 1895 1850 1805 1760 1710 1660 1615 16 2140 2095 2050 2005 1960 1915 1875 1830 1785 1740 17 2230 2190 2150 2110 2070 2025 1985 1945 1905 1860 18 Co...

Страница 10: ...1 2 1 2 1 2 20 20 20 50 45 60 50 0 5 5 25 20 30 25 20 15 10 20 15 40 10 5 15 10 Winter Design Temp F Unit Size 40 000 BTUH 60 000 BTUH Uninsulated 3 8 in Insulation 1 2 in Insulation Uninsulated 3 8 i...

Страница 11: ...0 1 5 4 6 4 6 3 0 1 5 6 1 4 6 4 6 3 0 6 1 6 1 4 6 3 0 Winter Design Temp C Unit Size 80 000 BTUH Uninsulated 3 8 in Insulation 1 2 in Insulation Pipe Dia mm 38 51 64 76 102 38 51 64 76 102 38 51 64 76...

Страница 12: ...00 40 155 185 20 100 175 200 15 55 130 175 200 20 80 175 200 10 75 185 5 65 155 2001 3000 65 190 35 150 175 95 165 185 10 49 125 165 185 15 75 165 185 70 175 N A 60 140 3001 4000 60 175 30 135 160 16...

Страница 13: ...g radius elbows use the highest number of elbows for either the vent or inlet pipe 3 x 3 ft 0 9 M 9 ft 2 7 M From Deductions from Maximum Equivalent Vent Length Ft M Table Add equiv length of 2 45 lon...

Страница 14: ...ow applications POSITION CLEARANCE Rear 0 0 mm Front Combustion air openings in furnace and in structure 1 in 25 mm Required for service Consult your local building codes 24 in 610 mm Recommended All...

Страница 15: ...le Offset X X X X X KGADA0301ALL Coil Adapter Kits Double Offset X X X X X KGARP0301B14 Return Air Base Upflow Applications 14 0 in wide X X X KGARP0301B17 Return Air Base Upflow Applications 17 5 in...

Страница 16: ...KGAVT0701CVT Vent Terminal Concentric 2 51 mm See Venting Tables KGAVT0801CVT Vent Terminal Concentric 3 76 mm KGAVT0101BRA Vent Terminal Bracket 2 51 mm KGAVT0201BRA Vent Terminal Bracket 3 76 mm KGA...

Страница 17: ...ter 20 508 mm MERV 8 FILXXCAR0020 X Cartridge Media Filter 20 508 mm MERV11 FILXXCAR0120 X Cartridge Media Filter 24 610 mm MERV 8 FILXXCAR0024 X Cartridge Media Filter 24 610 mm MERV11 FILXXCAR0124 X...

Отзывы: